SX-550-1701 Silex Technology, SX-550-1701 Datasheet - Page 34

WiFi / 802.11 Modules & Development Tools 802.11a/b/g Bridge Serial Server

SX-550-1701

Manufacturer Part Number
SX-550-1701
Description
WiFi / 802.11 Modules & Development Tools 802.11a/b/g Bridge Serial Server
Manufacturer
Silex Technology
Datasheet

Specifications of SX-550-1701

Interface Type
UART
Board Size
59.6 mm x 49.1 mm x 14.3 mm
Security
802.1xEAP, PEAP, WEP, WPAPSK, TKIP, WPA2, AES
Operating Voltage
3.3 VDC
Operating Temperature Range
0 C to + 50 C
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
3.
4.
Part Number 40183-101
program) to serial port 2 on the SX-550, you can configure an IP address using the internal command
console. To do this, set the terminal to 115.2Kbps, 8-bit characters, no parity, and no flow control.
Use the appropriate cable to connect the terminal to serial port 2 (if you are using the Evaluation
Daughtercard, the included serial cable will work for many devices). Press <Enter> and then enter
the following commands in response to the Local> prompt:
The SX-550 will restart, and you are then ready to configure it (skip the remainder of this section).
up a temporary ad hoc wireless connection as described in the following steps. Please note that
because this is a fairly complex process, we do not recommend it unless it is not possible to use a
wired connection.
If you can connect to an ASCII terminal (such as a PC running the HyperTerminal Accessory
SET IP ADDRESS ipaddress
INIT
EXIT
If you are using a wireless connection for the first-time configuration of the SX-550, you must set
d. You are now ready to configure the SX-550 (skip the remainder of this section).
a. Disconnect your PC and the SX-550 from your network, and temporarily set the PC
b. Power on the PC and the SX-550. You can connect to the SX-550 by specifying its
c. After you complete the entire SX-550 configuration process, you must set your PC back
settings as follows:
default IP address of 192.0.0.192 using a web browser as described in the next section.
When you have connected to the SX-550, you must then change the IP address and
enter the required wireless networking parameters for operation on your wireless
network.
to its original network settings.
address (for example, 00-0017-00-00-01).
You will see a reply from the SX-550 with the number of bytes and other
information if the address was successfully set.
If you get an error message or no response, then the IP address was not set. If
this is the case, the SX-550 may not be at its default configuration. To reset the
SX-550 to its default settings, hold down the test button on the Evaluation
Daughtercard for more than five seconds. If you are not using the evaluation
board, short GPIO7 on the OEM header to ground (4.7 K-ohm pull-up resistor
connected to +3.3VDC) for more than five seconds.
IP address: 192.0.0.191
Wireless Mode: Ad Hoc (sometimes referred to as Peer-to-Peer)
Channel: 11
SSID (or wireless network name): serserv
where ipaddress is the desired IP address.
Silex SX-550 Developer's Guide
Page 26

Related parts for SX-550-1701