SX-550-1701 Silex Technology, SX-550-1701 Datasheet - Page 37

WiFi / 802.11 Modules & Development Tools 802.11a/b/g Bridge Serial Server

SX-550-1701

Manufacturer Part Number
SX-550-1701
Description
WiFi / 802.11 Modules & Development Tools 802.11a/b/g Bridge Serial Server
Manufacturer
Silex Technology
Datasheet

Specifications of SX-550-1701

Interface Type
UART
Board Size
59.6 mm x 49.1 mm x 14.3 mm
Security
802.1xEAP, PEAP, WEP, WPAPSK, TKIP, WPA2, AES
Operating Voltage
3.3 VDC
Operating Temperature Range
0 C to + 50 C
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Using the Internal Command Console to Configure the SX-550
The Internal Command Console is a command line oriented method for configuring the SX-550. It
provides more comprehensive capabilities than either ExtendView or the Internal Web Pages, but is not
as easy to use. Advanced users may prefer to use this method because it is concise, fast, and powerful.
To use the Internal Command Console:
Part Number 40183-101
You may skip this section if you have completely configured the SX-550 using ExtendView or the SX-550 Internal Web
Pages. However, if you are using the bridge mode, you MUST use the Internal Command Console (see Chapter 4 for
information on configuring bridge mode.
1. The simplest way to access the Internal Command Console is via a terminal (for example, a
Windows PC running the HyperTerminal Accessory program) connected to serial port 2. If you
are using the SX-550-6900 Evaluation Daughtercard, the included serial cable can be used for
this purpose. If you are not using the Evaluation Daughtercard, then you must provide the
appropriate cable to connect pins 21, 22, and one of the ground pins on the OEM header to the
terminal (transmit data on the SX-550 must connect to receive data on the terminal, and vice-
versa). The terminal must be set for 115.2Kbps, 8-bit characters, no parity, and no flow control.
Silex SX-550 Developer's Guide
5. Select the appropriate wireless encryption
6. Configure the serial port settings so that they
configure the wireless security parameters.
Click the Submit button at the bottom of the
window (you may need to scroll) to save your
changes.
Now click I/O Port on the left side of the
screen to configure the serial port.
Click the Submit button at the bottom of the
window (you may need to scroll) to save your
changes.
When you have finished with all your
configuration changes, you must restart the
SX-550 for these changes to take effect.
You can skip the remainder of this chapter.
mode and enter the required settings (check
with your network administrator for the proper
settings if you do not know them). Appendix A
lists the possible encryption settings.
match the settings on your device. For
example, if your device is set for 9600bps,
odd parity, and XON/XOFF flow control, you
must change the settings on the SX-550 to
these settings.
Page 29