DP83849CVS/NOPB National Semiconductor, DP83849CVS/NOPB Datasheet - Page 54

IC TXRX ETHERNET PHY DUAL 80TQFP

DP83849CVS/NOPB

Manufacturer Part Number
DP83849CVS/NOPB
Description
IC TXRX ETHERNET PHY DUAL 80TQFP
Manufacturer
National Semiconductor
Type
Transceiverr
Datasheets

Specifications of DP83849CVS/NOPB

Number Of Drivers/receivers
2/2
Protocol
Ethernet
Voltage - Supply
3 V ~ 3.6 V
Mounting Type
Surface Mount
Package / Case
80-TQFP, 80-VQFP
Data Rate
100Mbps
Supply Voltage Range
3V To 3.6V
Logic Case Style
TQFP
No. Of Pins
80
Operating Temperature Range
0°C To +70°C
Msl
MSL 3 - 168 Hours
Filter Terminals
SMD
Rohs Compliant
Yes
Data Rate Max
10Mbps
For Use With
DP83849CVS-EVK - BOARD EVALUATION DP83849CVS
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Other names
*DP83849CVS
*DP83849CVS/NOPB
DP83849CVS

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
DP83849CVS/NOPB
Manufacturer:
NS
Quantity:
618
Part Number:
DP83849CVS/NOPB
Manufacturer:
Texas Instruments
Quantity:
10 000
www.national.com
7.1.7 Auto-Negotiation Link Partner Ability Register (ANLPAR) (Next Page)
10:0
Bit
15
14
13
12
11
Table 26. Auto-Negotiation Link Partner Ability Register (ANLPAR) (Next Page), address 05h
Bit Name
TOGGLE
CODE
ACK2
ACK
MP
NP
<000 0000 0000>,
Default
0, RO
0, RO
0, RO
0, RO
0, RO
RO
Next Page Indication:
1 = Link Partner desires Next Page Transfer.
0 = Link Partner does not desire Next Page Transfer.
Acknowledge:
1 = Link Partner acknowledges reception of the ability data word.
0 = Not acknowledged.
The Auto-Negotiation state machine will automatically control the
this bit based on the incoming FLP bursts. Software should not at-
tempt to write to this bit.
Message Page:
1 = Message Page.
0 = Unformatted Page.
Acknowledge 2:
1 = Link Partner does have the ability to comply to next page mes-
sage.
0 = Link Partner does not have the ability to comply to next page
message.
Toggle:
1 = Previous value of the transmitted Link Code word equalled 0.
0 = Previous value of the transmitted Link Code word equalled 1.
Code:
This field represents the code field of the next page transmission.
If the MP bit is set (bit 13 of this register), then the code shall be
interpreted as a “Message Page,” as defined in annex 28C of
Clause 28. Otherwise, the code shall be interpreted as an “Unfor-
matted Page,” and the interpretation is application specific.
54
Description

Related parts for DP83849CVS/NOPB