M28529G-12 Mindspeed Technologies, M28529G-12 Datasheet - Page 303

no-image

M28529G-12

Manufacturer Part Number
M28529G-12
Description
ATM IMA 8.192Mbps 1.8V/3.3V 484-Pin BGA
Manufacturer
Mindspeed Technologies
Datasheet

Specifications of M28529G-12

Package
484BGA
Utopia Type
Level 2
Typical Operating Supply Voltage
1.8|3.3 V
Minimum Operating Supply Voltage
1.71|3.135 V
Maximum Operating Supply Voltage
1.89|3.465 V
Maximum Output Rate
8.192 Mbps
Table 4-8.
28529-DSH-001-K
OAM.23
OAM.24
OAM.25
OAM.26
OAM.27
OAM.28
OAM.29
OAM.30
OAM.31
OAM.32
OAM.33
OAM.34
OAM.35
OAM.36
OAM.37
OAM.38
OAM.39
OAM.40
Item
Does the implementation increment SES-IMA-FE for every one second
interval containing one or more RDI-IMA defect, except during seconds
when a UAS-IMA-FE condition is reported, as indicated in Table 19 on page
77?
Does the period of NE unavailability begin at the onset of 10 contiguous
SES-IMA (including the first 10 seconds to enter the UAS-IMA condition), as
indicated in Table 19 on page 77?
Does the period of NE unavailability end at the onset of 10 contiguous
seconds with no SES-IMA (excluding the last 10 seconds to exit the UAS-
IMA condition), as indicated in Table 19 on page 77?
Does the implementation increment UAS-IMA for each one second interval
when the UAS-IMA condition is reported, as indicated in Table 19 on page
77?
Does the period of FE unavailability begin at the onset of 10 contiguous SES-
IMA (including the first 10 seconds to enter the UAS-IMA condition), as
indicated in Table 19 on page 77?
Does the period of FE unavailability end at the onset of 10 contiguous
seconds with no SES-IMA-FE (excluding the last 10 seconds to exit the UAS-
IMA-FE condition), as indicated in Table 19 on page 77?
Does the implementation increment UAS-IMA-FE for each one second
interval when the UAS-IMA-FE condition is reported, as indicated in Table 19
on page 77?
Does the implementation increment Tx-UUS-IMA for each second when the
NE Tx LSM is Unusable, as indicated in Table 19 on page 77?
Does the implementation increment Rx-UUS-IMA for each second when the
NE Rx LSM is Unusable, as indicated in Table 19 on page 77?
Does the implementation increment Tx-UUS-IMA-FE for each second when
the FE Tx LSM is reported Unusable, as indicated in Table 19 on page 77?
Does the implementation increment Rx-UUS-IMA-FE for each second when
the FE Rx LSM is reported Unusable, as indicated in Table 19 on page 77?
Does the implementation increment Tx-FC each time the Tx-Mis-Connected
link failure condition is entered, as indicated in Table 19 on page 77?
Does the implementation increment Tx-FC each time the Tx-Fault link failure
condition is entered, as indicated in Table 19 on page 77?
Does the implementation increment Rx-FC each time the LIF link failure
condition is entered, as indicated in Table 19 on page 77?
Does the implementation increment Rx-FC each time the LODS link failure
condition is entered, as indicated in Table 19 on page 77?
Does the implementation increment Rx-FC each time the Rx-Mis-Connected
link failure condition is entered, as indicated in Table 19 on page 77?
Does the implementation increment Rx-FC each time the Rx-Fault link failure
condition is entered, as indicated in Table 19 on page 77?
Does the implementation increment Tx-FC-FE each time the Tx-Unusable-FE
link failure condition is entered, as indicated in Table 19 on page 77?
IMA Interface OAM Operation Functions (3 of 5)
Protocol feature
Mindspeed Proprietary and Confidential
Mindspeed Technologies
®
Cond. for
Status
Status
Pred.
M
M
M
M
M
M
M
M
M
M
M
M
M
M
M
M
M
O
(R-127)
(R-128)
(R-128)
(R-128)
(R-129)
(R-129)
(R-129)
(R-130)
(R-131)
(R-132)
(R-133)
(R-134)
(R-134)
(R-135)
(R-135)
(R-135)
(R-135)
(O-21)
Ref.
Yes X No__
Yes X No__
Yes X No__
Yes X No__
Yes X No__
Yes X No__
Yes X No__
Yes X No__
Yes X No__
Yes X No__
Yes X No__
Yes X No__
Yes X No__
Yes X No__
Yes X No__
Yes X No__
Yes X No__
Yes X No__
Appendices
Support
288

Related parts for M28529G-12