AD9122 Analog Devices, AD9122 Datasheet - Page 37

no-image

AD9122

Manufacturer Part Number
AD9122
Description
Manufacturer
Analog Devices
Datasheet

Specifications of AD9122

Resolution (bits)
16bit
Dac Update Rate
1.23GSPS
Dac Settling Time
n/a
Max Pos Supply (v)
+3.47V
Single-supply
No
Dac Type
Current Out
Dac Input Format
LVDS,Par

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
AD9122AXCPZ
Manufacturer:
ADI
Quantity:
250
Part Number:
AD9122BCPZ
Manufacturer:
VISHAY
Quantity:
15 000
Part Number:
AD9122BCPZ
Manufacturer:
ADI
Quantity:
852
Part Number:
AD9122BCPZ
Manufacturer:
ADI/亚德诺
Quantity:
20 000
Company:
Part Number:
AD9122BCPZ
Quantity:
737
Part Number:
AD9122BCPZ-ND
Manufacturer:
ADI
Quantity:
31
Part Number:
AD9122BCPZRL
Manufacturer:
ARTESYN
Quantity:
125
Figure 52 shows the pass-band filter response for HB1. In most
applications, the usable bandwidth of the filter is limited by the
image suppression provided by the stop-band rejection and not
by the pass-band flatness. Table 16 shows the pass-band flatness
and stop-band rejection supported by the HB1 filter at different
bandwidths.
Table 16. HB1 Pass-Band and Stop-Band Performance by
Bandwidth
Bandwidth (% of f
80
80.4
81.2
82
83.6
85.6
–0.02
–0.04
–0.06
–0.08
–0.10
0.02
0
0
0.04
Figure 52. Pass-Band Detail of HB1
0.08
IN1
)
0.12
FREQUENCY (×
0.16
Pass-Band
Flatness (dB)
0.001
0.0012
0.0033
0.0076
0.0271
0.1096
0.20
0.24
f
IN1
) (Hz)
0.28
0.32
Stop-Band
Rejection (dB)
85
80
70
60
50
40
0.36
0
.
40
Rev. B | Page 37 of 60
Half-Band Filter 2 (HB2)
HB2 has eight modes of operation, as shown in Figure 53 and
Figure 54. The shape of the filter response is identical in each of
the eight modes. The eight modes are distinguished by two factors:
the filter center frequency and whether the input signal is
modulated by the filter.
As shown in Figure 53 and Figure 54, the center frequency in
each mode is offset by one-fourth the input data rate (f
the filter. Mode 0 through Mode 3 do not modulate the input
signal. Mode 4 through Mode 7 modulate the input signal by
f
operate independently and no mixing of the data between chan-
nels occurs. When operating in the other six modes, mixing of
the data between the I and Q paths occurs; therefore, the data
input to the filter is assumed to be complex.
IN2
. When operating in Mode 0 and Mode 4, the I and Q paths
–100
–100
–20
–40
–60
–80
–20
–40
–60
–80
0
0
0
0
MODE 0
0.2
0.2
MODE 1
0.4
Figure 53. HB2, Even Filter Modes
0.4
Figure 54. HB2, Odd Filter Modes
0.6
0.6
MODE 2
FREQUENCY (×
FREQUENCY (×
0.8
0.8
MODE 3
1.0
1.0
MODE 4
f
f
IN2
IN2
1.2
1.2
MODE 5
) (Hz)
) (Hz)
1.4
1.4
MODE 7
1.6
1.6
MODE 6
1.8
1.8
AD9122
IN2
2
2
) of
.0
.0

Related parts for AD9122