ADP5589 Analog Devices, ADP5589 Datasheet - Page 38

no-image

ADP5589

Manufacturer Part Number
ADP5589
Description
Keypad Decoder and I/O Expansion
Manufacturer
Analog Devices
Datasheet

Specifications of ADP5589

Vin Range
1.8 to 3.0V
Number Of I/os
19
Application
Mobil I-0 Exp-Keybd Cont,Mobil I-O Expander
Qwerty Keypad
Yes
Other Functions
I2C I/O & register
Function Flag
Mobil I-O
Package
24-Lead LFCSP,25-Ball WLCSP

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
ADP5589ACPZ-00-R7
Manufacturer:
ADI/亚德诺
Quantity:
20 000
ADP5589
GPIO_DIRECTION_C Register 0x32
Table 58. GPIO_DIRECTION_C Bit Descriptions
Bits
[7:3]
2
1
0
UNLOCK1 Register 0x33
Table 59. UNLOCK1 Bit Descriptions
Bits
7
[6:0]
UNLOCK2 Register 0x34
Table 60. UNLOCK2 Bit Descriptions
Bits
7
[6:0]
EXT_LOCK_EVENT Register 0x35
Table 61. EXT_LOCK_EVENT Bit Descriptions
Bits
7
[6:0]
Name
EXT_LOCK_STATE
EXT_LOCK_EVENT[6:0]
Name
GPIO_19_DIR
GPIO_18_DIR
GPIO_17_DIR
Name
UNLOCK1_STATE
UNLOCK1[6:0]
Name
UNLOCK2_STATE
UNLOCK2[6:0]
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
Description
Reserved.
0 = GPIO 19 is an input.
1 = GPIO 19 is an output.
0 = GPIO 18 is an input.
1 = GPIO 18 is an output.
0 = GPIO 17 is an input.
1 = GPIO 17 is an output.
Description
Defines which state the first unlock event should be
For key events:
0 = not applicable; releases not used for unlock.
1 = press is used as unlock event.
For GPIs and logic outputs configured for FIFO updates:
0 = inactive event used as reset condition.
1 = active event used as reset condition.
Defines the first event that must be detected to unlock the keypad after LOCK_EN has been set.
Description
Defines which state the second unlock event should be.
For key events:
0 = not applicable; releases not used for unlock.
1 = press is used as unlock event.
For GPIs and logic outputs configured for FIFO updates:
0 = inactive event used as reset condition.
1 = active event used as reset condition.
Defines the second event that must be detected to unlock the keypad after LOCK_EN has been set.
Description
Defines which state the lock event should be.
For key events:
0 = not applicable; releases not used for unlock.
1 = press is used as unlock event.
For GPIs and logic outputs configured for FIFO updates:
0 = inactive event used as reset condition.
1 = active event used as reset condition.
Defines an event that can lock the keypad.
When this event is detected, LOCK_INT is set.
Rev. A | Page 38 of 48