16-bit Microcontrollers - MCU 16BIT192KFLASH 11264 RAM
Manufacturer
Freescale Semiconductor
Datasheet

Specifications of S9S12GA192F0MLHR

Rohs
yes
Core
S12
Processor Series
MC9S12G
Data Bus Width
16 bit
Maximum Clock Frequency
25 MHz
Program Memory Size
192 KB
Data Ram Size
2 KB
On-chip Adc
Yes
Operating Supply Voltage
3.13 V to 5.5 V
Operating Temperature Range
- 40 C to + 125 C
Package / Case
LQFP-64
Mounting Style
SMD/SMT

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
S9S12GA192F0MLHR
Manufacturer:
AVX
Quantity:
40 000
Part Number:
S9S12GA192F0MLHR
Manufacturer:
Freescale Semiconductor
Quantity:
10 000
96 KByte Flash Module (S12FTMRG96K1V1)
Upon clearing CCIF to launch the Program P-Flash command, the Memory Controller will program the
data words to the supplied global address and will then proceed to verify the data words read back as
expected. The CCIF flag will set after the Program P-Flash operation has completed.
28.4.6.6
The Program Once command restricts programming to a reserved 64 byte field (8 phrases) in the
nonvolatile information register located in P-Flash. The Program Once reserved field can be read using the
Read Once command as described in
once since the nonvolatile information register in P-Flash cannot be erased. The Program Once command
must not be executed from the Flash block containing the Program Once reserved field to avoid code
runaway.
Upon clearing CCIF to launch the Program Once command, the Memory Controller first verifies that the
selected phrase is erased. If erased, then the selected phrase will be programmed and then verified with
read back. The CCIF flag will remain clear, setting only after the Program Once operation has completed.
1020
1
As defined by the memory map for FTMRG96K1.
Register
FSTAT
Program Once Command
1
CCOBIX[2:0]
Global address [2:0] must be 000
MGSTAT1
MGSTAT0
ACCERR
Error Bit
Table 28-42. Program Once Command FCCOB Requirements
FPVIOL
000
001
010
011
100
101
Table 28-41. Program P-Flash Command Error Handling
MC9S12G Family Reference Manual,
Set if CCOBIX[2:0] != 101 at command launch
Set if command not available in current mode (see
Set if an invalid global address [17:0] is supplied see
Set if a misaligned phrase address is supplied (global address [2:0] != 000)
Set if the global address [17:0] points to a protected area
Set if any errors have been encountered during the verify operation
Set if any non-correctable errors have been encountered during the verify
operation
Section
Program Once phrase index (0x0000 - 0x0007)
0x07
28.4.6.4. The Program Once command must only be issued
Program Once word 0 value
Program Once word 1 value
Program Once word 2 value
Program Once word 3 value
FCCOB Parameters
Error Condition
Rev.1.23
Not Required
Table
Table
28-27)