AT91SAM7S321-AU Atmel, AT91SAM7S321-AU Datasheet - Page 74

IC ARM7 MCU FLASH 32K 64LQFP

AT91SAM7S321-AU

Manufacturer Part Number
AT91SAM7S321-AU
Description
IC ARM7 MCU FLASH 32K 64LQFP
Manufacturer
Atmel
Series
AT91SAMr

Specifications of AT91SAM7S321-AU

Core Processor
ARM7
Core Size
16/32-Bit
Speed
55MHz
Connectivity
I²C, SPI, SSC, UART/USART, USB
Peripherals
Brown-out Detect/Reset, DMA, POR, PWM, WDT
Number Of I /o
32
Program Memory Size
32KB (32K x 8)
Program Memory Type
FLASH
Ram Size
8K x 8
Voltage - Supply (vcc/vdd)
1.65 V ~ 1.95 V
Data Converters
A/D 8x10b
Oscillator Type
Internal
Operating Temperature
-40°C ~ 85°C
Package / Case
64-LQFP
Processor Series
AT91SAMx
Core
ARM7TDMI
Data Bus Width
32 bit
Data Ram Size
8 KB
Interface Type
I2C, I2S, SPI, SSC, TWI, UART, USB
Maximum Clock Frequency
55 MHz
Number Of Programmable I/os
32
Number Of Timers
10 bit
Operating Supply Voltage
1.8 V to 3.3 V
Maximum Operating Temperature
+ 85 C
Mounting Style
SMD/SMT
3rd Party Development Tools
JTRACE-ARM-2M, KSK-AT91SAM7S-PL, MDK-ARM, RL-ARM, ULINK2
Development Tools By Supplier
AT91SAM-ICE, AT91-ISP, AT91SAM7S-EK
Minimum Operating Temperature
- 40 C
On-chip Adc
10 bit, 8 Channel
Controller Family/series
AT91SAM7xxxx
No. Of I/o's
32
Ram Memory Size
8KB
Cpu Speed
55MHz
No. Of Timers
3
Rohs Compliant
Yes
For Use With
AT91SAM-ICE - EMULATOR FOR AT91 ARM7/ARM9AT91SAM7S-EK - KIT EVAL FOR ARM AT91SAM7S
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Eeprom Size
-
Lead Free Status / Rohs Status
Lead free / RoHS Compliant

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
AT91SAM7S321-AU
Manufacturer:
Atmel
Quantity:
10 000
Part Number:
AT91SAM7S321-AU-999
Manufacturer:
Atmel
Quantity:
10 000
74
AT91SAM7S Series Preliminary
The Real-time Timer value (CRTV) can be read at any time in the register RTT_VR (Real-time
Value Register). As this value can be updated asynchronously from the Master Clock, it is advis-
able to read this register twice at the same value to improve accuracy of the returned value.
The current value of the counter is compared with the value written in the alarm register
RTT_AR (Real-time Alarm Register). If the counter value matches the alarm, the bit ALMS in
RTT_SR is set. The alarm register is set to its maximum value, corresponding to 0xFFFF_FFFF,
after a reset.
The bit RTTINC in RTT_SR is set each time the Real-time Timer counter is incremented. This bit
can be used to start a periodic interrupt, the period being one second when the RTPRES is pro-
grammed with 0x8000 and Slow Clock equal to 32.768 Hz.
Reading the RTT_SR status register resets the RTTINC and ALMS fields.
Writing the bit RTTRST in RTT_MR immediately reloads and restarts the clock divider with the
new programmed value. This also resets the 32-bit counter.
Note:
Figure 14-2. RTT Counting
RTTINC (RTT_SR)
ALMS (RTT_SR)
APB Interface
RTPRES - 1
Because of the asynchronism between the Slow Clock (SCLK) and the System Clock (MCK):
1) The restart of the counter and the reset of the RTT_VR current value register is effective only 2
slow clock cycles after the write of the RTTRST bit in the RTT_MR register.
2) The status register flags reset is taken into account only 2 slow clock cycles after the read of the
RTT_SR (Status Register).
Prescaler
MCK
RTT
0
0
...
APB cycle
ALMV-1
ALMV
read RTT_SR
ALMV+1
ALMV+2
6175K–ATARM–30-Aug-10
APB cycle
ALMV+3