LAN8710A-EZK-TR SMSC, LAN8710A-EZK-TR Datasheet - Page 34

no-image

LAN8710A-EZK-TR

Manufacturer Part Number
LAN8710A-EZK-TR
Description
Ethernet ICs 10/100 Ethernet XCVR w/HPAutoMDIX FlexPwr
Manufacturer
SMSC
Type
Single Chipr
Datasheet

Specifications of LAN8710A-EZK-TR

Minimum Operating Temperature
0 C
Mounting Style
SMD/SMT
Product
Ethernet Transceivers
Number Of Transceivers
1
Standard Supported
IEEE 802.3 or IEEE 802.3u
Data Rate
125 Mbps
Supply Voltage (max)
3.6 V
Supply Voltage (min)
1.6 V or 3 V
Maximum Operating Temperature
+ 85 C
Package / Case
QFN
Lead Free Status / RoHS Status
Lead free / RoHS Compliant

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
LAN8710A-EZK-TR
Manufacturer:
SMSC
Quantity:
10 000
Part Number:
LAN8710A-EZK-TR
Manufacturer:
SMSC
Quantity:
20 000
Part Number:
LAN8710A-EZK-TR
0
Company:
Part Number:
LAN8710A-EZK-TR
Quantity:
2 000
Revision 1.2 (11-10-10)
3.6.2
30.7
30.6
30.5
30.4
30.3
30.2
30.1
MASK
29.7
29.6
29.5
29.4
29.3
29.2
29.1
INTERRUPT SOURCE
Alternate Interrupt System
The Alternate interrupt system is enabled by setting the
to “1”. In this mode, to set an interrupt, set the corresponding bit of the in the Mask Register 30, (see
Table
deassert the nINT output, or clear the interrupt source, and write a ‘1’ to the corresponding Interrupt
Source Flag. Writing a ‘1’ to the Interrupt Source Flag will cause the state machine to check the
Interrupt Source to determine if the Interrupt Source Flag should clear or stay as a ‘1’. If the Condition
to deassert is true, then the Interrupt Source Flag is cleared and nINT is also deasserted. If the
Condition to deassert is false, then the Interrupt Source Flag remains set, and the nINT remains
asserted.
For example, setting the
After a cable is plugged in, the
nINT will be asserted low. To de-assert the nINT interrupt output, either clear the
the
Interrupt Mask
Note: The
Mode Control/Status Register
ENERGYON
Auto-Negotiation
complete
Remote Fault
Detected
Link Down
Auto-Negotiation
LP Acknowledge
Parallel
Detection Fault
Auto-Negotiation
Page Received
3.4). To Clear an interrupt, either clear the corresponding bit in the
FLAG
as a ‘1’ at power-up. If no signal is present, then both
a few milliseconds.
signal acquisition process, therefore the
as a ‘1’ at power-up. If no signal is present, then both
a few milliseconds.
ENERGYON
Table 3.4 Alternative Interrupt System Management Table
Register, OR clear the INT7 mask (bit 7 of the
INT7
bit in the
17.1
1.5
1.4
1.2
5.14
6.4
6.1
INTERRUPT SOURCE
bit in the
ENERGYON
Link Status
ENERGYON
Auto-Negotiate
Complete
Remote Fault
Acknowledge
Parallel Detection
Fault
Page Received
by removing the cable and then writing a ‘1’ to the
DATASHEET
Small Footprint MII/RMII 10/100 Ethernet Transceiver with HP Auto-MDIX and flexPWR
Mode Control/Status Register
Interrupt Mask Register
34
bit in the
INT7
Rising 17.1
Rising 1.5
Rising 1.4
Falling 1.2
Rising 5.14
Rising 6.4
Rising 6.1
bit in the
ASSERT nINT
ALTINT
Mode Control/Status Register
EVENT TO
ENERGYON
Interrupt Mask
ENERGYON
bit of the
Interrupt Mask Register
will enable the ENERGYON interrupt.
is defaulted to a ‘1’ at the start of the
17.1 low
1.5 low
1.4 low
1.2 high
5.14 low
6.4 low
6.1 low
Mode Control/Status Register
DE-ASSERT
CONDITION
Interrupt Mask Register
SMSC LAN8710A/LAN8710Ai
and
and
Register).
TO
INT7
INT7
ENERGYON
goes active and
will clear within
will clear within
INT7
will also read
29.7
29.6
29.5
29.4
29.3
29.2
29.1
CLEAR
BIT TO
Datasheet
®
bit in the
nINT
Technology
bit in
to

Related parts for LAN8710A-EZK-TR