AT90USB647-MU Atmel, AT90USB647-MU Datasheet - Page 377

no-image

AT90USB647-MU

Manufacturer Part Number
AT90USB647-MU
Description
MCU, 8BIT, 64K FLASH, USB, 64QFN
Manufacturer
Atmel
Datasheets

Specifications of AT90USB647-MU

Controller Family/series
AT90
No. Of I/o's
48
Eeprom Memory Size
2KB
Ram Memory Size
4KB
Cpu Speed
16MHz
No. Of
RoHS Compliant
Core Size
8bit
Program Memory Size
64KB
Oscillator Type
External, Internal
Package
64QFN EP
Device Core
AVR
Family Name
AT90
Maximum Speed
20 MHz
Ram Size
4 KB
Operating Supply Voltage
3.3|5 V
Data Bus Width
8 Bit
Program Memory Type
Flash
Number Of Programmable I/os
48
Interface Type
SPI/TWI/USART/USB
On-chip Adc
8-chx10-bit
Operating Temperature
-40 to 85 °C
Number Of Timers
4
Lead Free Status / Rohs Status
 Details

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
AT90USB647-MU
Manufacturer:
AAT
Quantity:
18 240
Part Number:
AT90USB647-MUR
Manufacturer:
AD
Quantity:
2 747
29.6.9
29.6.10
29.6.11
7593K–AVR–11/09
Programming the Fuse High Bits
Programming the Extended Fuse Bits
Programming the Lock Bits
The algorithm for programming the Fuse High bits is as follows (refer to
Flash” on page 373
The algorithm for programming the Extended Fuse bits is as follows (refer to
Flash” on page 373
Figure 29-5. Programming the FUSES Waveforms
The algorithm for programming the Lock bits is as follows (refer to
page 373
The Lock bits can only be cleared by executing Chip Erase.
1. A: Load Command “0100 0000”.
2. C: Load Data Low Byte. Bit n = “0” programs and bit n = “1” erases the Fuse bit.
3. Set BS2, BS1 to “01”. This selects high data byte.
4. Give WR a negative pulse and wait for RDY/BSY to go high.
5. Set BS2, BS1 to “00”. This selects low data byte.
1. 1. A: Load Command “0100 0000”.
2. 2. C: Load Data Low Byte. Bit n = “0” programs and bit n = “1” erases the Fuse bit.
3. 3. Set BS2, BS1 to “10”. This selects extended data byte.
4. 4. Give WR a negative pulse and wait for RDY/BSY to go high.
5. 5. Set BS2, BS1 to “00”. This selects low data byte.
1. A: Load Command “0010 0000”.
2. C: Load Data Low Byte. Bit n = “0” programs the Lock bit. If LB mode 3 is programmed
3. Give WR a negative pulse and wait for RDY/BSY to go high.
RESET +12V
(LB1 and LB2 is programmed), it is not possible to program the Boot Lock bits by any
External Programming mode.
RDY/BSY
PAGEL
XTAL1
DATA
for details on Command and Data loading):
XA1
XA0
BS1
BS2
WR
OE
0x40
A
for details on Command and Data loading):
for details on Command and Data loading):
DATA
C
Write Fuse Low byte
XX
0x40
A
DATA
C
Write Fuse high byte
XX
AT90USB64/128
“Programming the Flash” on
0x40
A
DATA
C
Write Extended Fuse byte
“Programming the
“Programming the
XX
377

Related parts for AT90USB647-MU