TOOTHPIC RF Solutions, TOOTHPIC Datasheet - Page 70

MODULE, BLUETOOTH, DATA ACQUISITION

TOOTHPIC

Manufacturer Part Number
TOOTHPIC
Description
MODULE, BLUETOOTH, DATA ACQUISITION
Manufacturer
RF Solutions
Datasheet

Specifications of TOOTHPIC

Svhc
No SVHC (15-Dec-2010)
Error Response
The response byte 0x02 indicates that an error has occurred. The byte after the response byte is the Error
Byte, which specifies the exact error that occurred:
In addition, if the On internal error… property specifies that internal errors should be reported to the host, the
error byte may equal any of the ErrorStatus, BMTE_Error, BMTE_Warning error values.
Date Time Response
The response byte 0x03 reports the current date and time to the host. The 8 bytes after the response byte
are the date and time in DateTimeU format.
I/O Value Response
The response byte 0x04 reports an I/O input value to the host. The first byte after the response byte
indicates which value is being reported and matches those used in the Get I/O Command. The remaining
byte(s) will contain the reported value. The size will vary according to data type as shown in the examples
below.
Page 70
9-Apr-06
Error Response Error Values
Error Byte
0xF0
0xF1
0xF2
Error Response Examples
Queue full (binary)
Not understood (ASCII)
ErrorStatus error
Memory Failure (binary)
General BlueMatik error
(ASCII)
Date Time Response Examples – 13:24:50, Friday, April 1st, 2005
Date Time (binary)
Date Time (ASCII)
I/O Value Response Examples
SDO digital input high (binary)
SDO digital input low (ASCII)
AN3 analog input 0x234 (range 0
to 1023) (ASCII)
Parallel A (7-bit) analog input
0x14 (range 0 to 31) (ASCII)
Toothpick 3.0.00007
Error Name
Queue full
Not understood
Ping Fail
DS380-8
0x03 0x02 0xF0
“<CR><LF>0302F1<CR><LF>”
0x03 0x02 0x0B
“<CR><LF>03020F<CR><LF>”
0x0A 0x03 0x32 0x18 0x0D 0x01 0x05 0x04
0xD5 0x07
“<CR><LF>0A0332180D010504D507<CR><LF>”
0x04 0x04 0x25 0x01
“<CR><LF>04042500<CR><LF>”
“<CR><LF>0504130234<CR><LF>”
“<CR><LF>04040614<CR><LF>”
© FlexiPanel Ltd
Interpretation
The message queue filled up and some
messages were lost
The previous command was not understood
A FxPE_PingFail ping failure occurred
Patents apply and/or pending
www.FlexiPanel.com

Related parts for TOOTHPIC