MPU-6050 INVENSENSE, MPU-6050 Datasheet - Page 29

no-image

MPU-6050

Manufacturer Part Number
MPU-6050
Description
GYRO/ACCEL, 9-AXIS FUSION, PROG, I2C
Manufacturer
INVENSENSE
Datasheet

Specifications of MPU-6050

No. Of Axes
9
Sensor Case Style
QFN
No. Of Pins
24
Supply Voltage Range
2.5V To 3.6V
Operating Temperature Range
-40°C To +85°C
Interface
I2C
Acceleration Range
± 2g, ± 4g, ± 8g, ± 16g
Interface Type
I2C, SPI
Rohs Compliant
Yes
Lead Free Status / RoHS Status
Lead free / RoHS Compliant

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
MPU-6050
Manufacturer:
INVENSEN
Quantity:
13 000
Part Number:
MPU-6050
Manufacturer:
INVENSE
Quantity:
20 000
Part Number:
MPU-6050
0
Company:
Part Number:
MPU-6050
Quantity:
8 000
Part Number:
MPU-6050A
Manufacturer:
INVENSENS
Quantity:
20 000
Part Number:
MPU-6050C
Manufacturer:
FREESCALE
Quantity:
9 440
Part Number:
MPU-6050C
Manufacturer:
INVENSENMSE
Quantity:
20 000
Company:
Part Number:
MPU-6050C
Quantity:
3 000
Part Number:
MPU-6050ES
Manufacturer:
INVENSE
Quantity:
20 000
Part Number:
MPU-6050M
Manufacturer:
INVENSE
Quantity:
20 000
Part Number:
MPU-6050MPU-6050MPU-6050
0
counter threshold, a motion interrupt is triggered. The axis and polarity which caused the interrupt to be
triggered is flagged in the MOT_DETECT_STATUS register.
Like with Free Fall detection, Motion detection has a configurable acceleration threshold MOT_THR specified
in steps of 1 mg. The counter threshold MOT_DUR is specified in steps of 1 ms. The decrement rate has the
same options as Free Fall detection, and is specified in the MOT_DETECT_CTRL register.
Zero Motion detection capability uses the digital high pass filter (DHPF) and a similar threshold scheme to
Free Fall detection. Each axis of the high passed accelerometer measurement must have an absolute value
less than a threshold specified in the ZRMOT_THR register. This increments a counter, which generates an
interrupt when reaching the threshold specified in ZRMOT_DUR.
Unlike Free Fall or Motion detection, Zero Motion detection triggers an interrupt both when Zero Motion is
first detected and when Zero Motion is no longer detected. While Free Fall and Motion are indicated with a
flag which clears after being read, reading the state of the Zero Motion detected from the
MOT_DETECT_STATUS register does not clear its status.
8.4
Zero Motion Interrupt
MPU-6000/MPU-6050 Product Specification
29 of 53