KMA199,115 NXP Semiconductors, KMA199,115 Datasheet - Page 27

IC SENSOR PROG ANGLE SOT880

KMA199,115

Manufacturer Part Number
KMA199,115
Description
IC SENSOR PROG ANGLE SOT880
Manufacturer
NXP Semiconductors
Datasheet

Specifications of KMA199,115

Operational Type
Programmable Angle Sensor
Operating Supply Voltage
5 V
Supply Current
5 mA to 10 mA
Package / Case
SOT-880
Mounting Style
Through Hole
Supply Voltage (min)
4.5 V
Supply Voltage (max)
5.5 V
Maximum Output Current
20 mA
Lead Free Status / RoHS Status
Lead free / RoHS Compliant

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
KMA199,115
Manufacturer:
NXP/恩智浦
Quantity:
20 000
NXP Semiconductors
14. Electromagnetic compatibility
KMA199_1
Product data sheet
14.1.1 Conducted radio disturbance
14.1.2 Radiated radio disturbance
14.2.1 Absorber lined shielded enclosure
14.1 Emission (CISPR 25)
14.2 Radiated disturbances (ISO 11452-1 third edition (2005-02),
If the magnetic field angle is larger than the CLAMP_SW_ANGLE, the output switches to
CLAMP_LO for a positive slope. The value of CLAMP_SW_ANGLE can be calculated
from other EEPROM constants but must be programmed.
EMC is verified in an independent and certified test laboratory.
Tests according to CISPR 25 were fulfilled.
Test of the device according to CISPR 25, third edition (2008-03), Chapter 6.2.
Class: 5.
Test of the device according to CISPR 25, third edition (2008-03), Chapter 6.4.
Class: 5 (without addition of 6 dB in FM band).
ISO 11452-2, ISO 11452-4 and ISO 11452-5)
The common understanding of the requested function is that an effect is tolerated as
described in
and may differ from the final application.
Table 24.
Tests according to ISO 11452-2, second edition (2004-11), were fulfilled.
Test levels:
State: A.
CLAMP_SW_ANGLE
Parameter
Variation of output signal in analog
output mode
200 V/m; 200 MHz to 400 MHz (step 10 MHz)
200 V/m; 400 MHz to 1 000 MHz (step 25 MHz)
200 V/m; 1 GHz to 10 GHz (step 100 MHz)
Failure condition for radiated disturbances
Table 24
All information provided in this document is subject to legal disclaimers.
=
during the disturbance. The reachable values are setup dependent
1
-- -
2
Rev. 01 — 26 April 2010
×
1
+
CLAMP_HI CLAMP_LO
--------------------------------------------------------------------
Comment
value measured relative to the
output at test start
8192
×
---------------------------------------------- -
ANG_RNG_MULT
Programmable angle sensor
1
Min
-
© NXP B.V. 2010. All rights reserved.
KMA199
Max
±0.9
Unit
%V
27 of 36
DD
(12)