KMA199,115 NXP Semiconductors, KMA199,115 Datasheet - Page 5

IC SENSOR PROG ANGLE SOT880

KMA199,115

Manufacturer Part Number
KMA199,115
Description
IC SENSOR PROG ANGLE SOT880
Manufacturer
NXP Semiconductors
Datasheet

Specifications of KMA199,115

Operational Type
Programmable Angle Sensor
Operating Supply Voltage
5 V
Supply Current
5 mA to 10 mA
Package / Case
SOT-880
Mounting Style
Through Hole
Supply Voltage (min)
4.5 V
Supply Voltage (max)
5.5 V
Maximum Output Current
20 mA
Lead Free Status / RoHS Status
Lead free / RoHS Compliant

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
KMA199,115
Manufacturer:
NXP/恩智浦
Quantity:
20 000
NXP Semiconductors
6. Analog output
KMA199_1
Product data sheet
Since the Anisotropic MR (AMR) effect is periodic over 180°, the sensor output is also
180°-periodic, where the angle is calculated relative to a freely programmable zero angle.
The dashed line indicates the mechanical zero degree position.
The KMA199 provides one analog output signal on pin OUT/DATA. The measured angle
α is converted linearly into a value, which is ratiometric to the supply voltage V
positive or a negative slope is provided for this purpose.
The following table describes the analog output behavior for a positive slope. If for
example, a magnetic field angle, above the programmed maximum angle α
the clamp switch angle α
upper clamping voltage. If the magnetic field angle is larger than the clamp switch angle,
the analog output switches from upper to lower clamping voltage. In the case of a
negative slope, the clamping voltages are changed.
Table 3.
The analog output voltage range codes both angular and diagnostic information. A valid
angle value is between the upper and lower clamping voltage. If the analog output is in the
diagnostic range, that is below 4 %V
detected. The analog output repeats every 180°.
Magnetic field angle
α
α
Fig 2.
max
sw(CL)
< α < α
< α < α
Angular measurement directions
Analog output behavior for a positive slope
sw(CL)
ref
All information provided in this document is subject to legal disclaimers.
+ 180°
Rev. 01 — 26 April 2010
sw(CL)
is applied to the sensor, then analog output is set to the
DD
or above 96 %V
Analog output
V
V
(CL)u
(CL)l
DD
, an error condition has been
001aag741
Programmable angle sensor
H
ext
© NXP B.V. 2010. All rights reserved.
KMA199
max
DD
, but below
. Either a
5 of 36