Specifications of KMA199,115
Operational Type
Programmable Angle Sensor
Operating Supply Voltage
5 V
Supply Current
5 mA to 10 mA
Package / Case
SOT-880
Mounting Style
Through Hole
Supply Voltage (min)
4.5 V
Supply Voltage (max)
5.5 V
Maximum Output Current
20 mA
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Available stocks
Company
Part Number
Manufacturer
Quantity
Price
Part Number:
KMA199,115
Manufacturer:
NXP/恩智浦
Quantity:
20 000
NXP Semiconductors
KMA199_1
Product data sheet
14.2.2 Bulk-current injection
14.2.3 Strip line
14.2.4 Immunity against mobile phones
14.3 Electrical transient transmission by capacitive coupling [ISO 7637-3,
Tests according to ISO 11452-4, third edition (2005-04), were fulfilled.
Test level: 200 mA with C
State: A.
Tests according to ISO 11452-5, second edition (2002-04), were fulfilled.
Test level: 200 V/m with C
State: A.
Tests according to ISO 11452-2, second edition (2004-11), were fulfilled.
State: A.
Definition of Global System for Mobile Communications (GSM) signal:
In deviation of ISO 11452-2 a GSM signal (definition see above) instead of an AM signal
was used.
first edition (1995-07)]
The common understanding of the requested function is that an effect is tolerated as
described in
Table 25.
Tests according to ISO 7637-3 were fulfilled.
Severity level: IV (for pulse 3a and 3b).
Class: B for pulse 3a, B for pulse 3b.
Parameter
Variation of output signal in analog
output mode
•
•
•
•
•
Pulse modulation: per GSM specification (217 Hz; 12.5 % duty cycle)
Modulation grade: ≥ 60 dB
Sweep: linear 800 MHz to 3 GHz (duration 10 s at 890 MHz, 940 MHz and 1.8 GHz
band)
Antenna polarization: vertical, horizontal
Field strength: 200 V/m during on-time [calibration in Continuous Wave (CW)]
Failure condition for electrical transient transmission
Table 25
All information provided in this document is subject to legal disclaimers.
during the disturbance.
Rev. 01 — 26 April 2010
L
L
= 1 nF.
= 1 nF; extended up to 1 GHz.
Comment
value measured relative to the
output at test start
Programmable angle sensor
Min
-
© NXP B.V. 2010. All rights reserved.
KMA199
Max
±0.9
Unit
%V
28 of 36
DD