Specifications of LAN9115-MT

Operating Supply Voltage (typ)
3.3V
Operating Supply Voltage (min)
2.97V
Operating Supply Voltage (max)
3.63V
Operating Temperature Classification
Commercial
Mounting
Surface Mount
Pin Count
100
Lead Free Status / RoHS Status
Compliant

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
LAN9115-MT
Manufacturer:
Standard
Quantity:
1 907
Part Number:
LAN9115-MT
Manufacturer:
SMSC
Quantity:
672
Part Number:
LAN9115-MT
Manufacturer:
Microchip Technology
Quantity:
10 000
Part Number:
LAN9115-MT
Manufacturer:
SMSC
Quantity:
1 000
Part Number:
LAN9115-MT
Manufacturer:
SMSC/PBF
Quantity:
182
Part Number:
LAN9115-MT
Manufacturer:
SMSC
Quantity:
20 000
Company:
Part Number:
LAN9115-MT
Quantity:
2
Company:
Part Number:
LAN9115-MT
Quantity:
124
Company:
Part Number:
LAN9115-MT
Quantity:
106
Part Number:
LAN9115-MT-E2
Manufacturer:
SMSC
Quantity:
3 994
Part Number:
LAN9115-MT-E2
Manufacturer:
SMSC
Quantity:
20 000
Highly Efficient Single-Chip 10/100 Non-PCI Ethernet Controller
Datasheet
SMSC LAN9115
5.4.8
31-16
BITS
15-3
2
1
0
Pause Time (FCPT). This field indicates the value to be used in the PAUSE TIME field in the control
frame. This field must be initialized before full-duplex automatic flow control is enabled.
Reserved
Pass Control Frames (FCPASS). When set, the MAC sets the Packet Filter bit in the Receive packet
status to indicate to the Application that a valid Pause frame has been received. The Application must
accept or discard a received frame based on the Packet Filter control bit. The MAC receives, decodes
and performs the Pause function when a valid Pause frame is received in Full-Duplex mode and when
flow control is enabled (FCE bit set). When reset, the MAC resets the Packet Filter bit in the Receive
packet status.
The MAC always passes the data of all frames it receives (including Flow Control frames) to the
Application. Frames that do not pass Address filtering, as well as frames with errors, are passed to
the Application. The Application must discard or retain the received frame’s data based on the
received frame’s STATUS field. Filtering modes (Promiscuous mode, for example) take precedence
over the FCPASS bit.
Flow Control Enable (FCEN). When set, enables the MAC Flow Control function. The MAC decodes
all incoming frames for control frames; if it receives a valid control frame (PAUSE command), it
disables the transmitter for a specified time (Decoded pause time x slot time). When reset, the MAC
flow control function is disabled; the MAC does not decode frames for control frames.
Note:
Flow Control Busy (FCBSY).
transmitted. This bit should read logical 0 before writing to the Flow Control (FLOW) register. During
a transfer of Control Frame, this bit continues to be set, signifying that a frame transmission is in
progress. After the PAUSE control frame’s transmission is complete, the MAC resets to 0.
Notes:
FLOW—Flow Control Register
This register controls the generation and reception of the Control (Pause command) frames by the
MAC’s flow control block. The control frame fields are selected as specified in the 802.3x Specification
and the Pause-Time value from this register is used in the “Pause Time” field of the control frame. In
full-duplex mode the FCBSY bit is set until the control frame is transferred onto the cable. In half-
duplex mode FCBSY is set while back pressure is being asserted. The host has to make sure that the
Busy bit is cleared before writing the register. The Pass Control Frame bit (FCPASS) does not affect
the sending of the frames, including Control Frames, to the Application Interface. The Flow Control
Enable (FCEN) bit enables the receive portion of the Flow Control block.
This register is used in conjunction with the AFC_CFG register in the Slave CSRs to configure flow
control. Software flow control is initiated using the AFC_CFG register.
Note: The LAN9115 will not transmit pause frames or assert back pressure if the transmitter is
When writing this register the FCBSY bit must always be zero.
Applications must always write a zero to this bit
Offset:
Default Value:
disabled.
Flow Control is applicable when the MAC is set in Full Duplex Mode. In Half-Duplex mode,
this bit enables the Backpressure function to control the flow of received frames to the MAC.
8
00000000h
This bit is set high whenever a pause frame or back pressure is being
DATASHEET
105
DESCRIPTION
Attribute:
Size:
R/W
32 bits
Revision 1.5 (07-11-08)