PEB3081FV14XP Lantiq, PEB3081FV14XP Datasheet - Page 133

PEB3081FV14XP

Manufacturer Part Number
PEB3081FV14XP
Description
Manufacturer
Lantiq
Datasheet

Specifications of PEB3081FV14XP

Number Of Line Interfaces
1
Control Interface
HDLC
Lead Free Status / Rohs Status
Compliant
Preliminary
4.1.2
Value after reset: F3
CIR0
CODR0 ... C/I Code 0 Receive
Value of the received Command/Indication code. A C/I-code is loaded in CODR0 only
after being the same in two consecutive IOM-frames and the previous code has been
read from CIR0.
CIC0 ... C/I Code 0 Change
A change in the received Command/Indication code has been recognized. This bit is set
only when a new code is detected in two consecutive IOM-frames. It is reset by a read
of CIR0.
CIC1 ... C/I Code 1 Change
A change in the received Command/Indication code in IOM-channel 1 has been
recognized. This bit is set when a new code is detected in one IOM-frame. It is reset by
a read of CIR0.
S/G ... Stop/Go Bit Monitoring
Indicates the availability of the upstream D-channel on the S/T interface.
1: Stop
0: Go
BAS ... Bus Access Status
Indicates the state of the TIC-bus:
0: the SBCX-X itself occupies the D- and C/I-channel
1: another device occupies the D- and C/I-channel
Note: The CODR0 bits are updated every time a new C/I-code is detected in two
Data Sheet
consecutive IOM-frames. If several consecutive valid new codes are detected and
CIR0 is not read, only the first and the last C/I code is made available in CIR0 at
the first and second read of that register, respectively.
7
CIR0 - Command/Indication Receive 0
H
CODR0
133
CIC0
CIC1
Detailed Register Description
S/G
0
BAS
PEB 3081
PEF 3081
2000-09-27
RD (2E)