PEB3081FV14XP Lantiq, PEB3081FV14XP Datasheet - Page 99

PEB3081FV14XP

Manufacturer Part Number
PEB3081FV14XP
Description
Manufacturer
Lantiq
Datasheet

Specifications of PEB3081FV14XP

Number Of Line Interfaces
1
Control Interface
HDLC
Lead Free Status / Rohs Status
Compliant
Preliminary
3.7.3
The IOM-2 MONITOR channel (see
MONITOR channel between a master mode device and a slave mode device.
The MONTIOR channel data can be controlled by the bits in the MONITOR control
register (MON_CR). For the transmission of the MONITOR data one of the IOM-2
channels (3 IOM-2 channels in TE mode, 8 channels in non TE mode) can be selected
by setting the MONITOR channel selection bits (MCS) in the MONITOR control register
(MON_CR).
The DPS bit in the same register selects between an output on DU or DD respectively
and with EN_MON the MONITOR data can be enabled/disabled. The default value is
MONITOR channel 0 (MON0) enabled and transmission on DD.
Figure 52
The MONITOR channel of the SBCX-X can be used in following applications which are
illustrated in
• As a master device the SBCX-X can program and control other devices attached to
Data Sheet
the IOM-2 which do not need a parallel microcontroller interface e.g. ARCOFI-BA PSB
2161. This facilitates redesigning existing terminal designs in which e.g. an interface
of an expansion slot is realized with IOM-2 interface and monitor programming.
(e.g. ARCOFI-BA)
V/D Module
IOM-2 Monitor Channel
Figure
Examples of MONITOR Channel Applications in IOM-2 TE Mode
IOM-2 MONITOR Channel
Master
Device
52:
MONITOR Handler
µC
Layer 1
Figure
99
52) is utilized for information exchange in the
Data Exchange between
two µC Systems
(e.g. ISAR34)
(e.g. ISAR34)
V/D Module
V/D Module
µC
µC
Description of Functional Blocks
IOM-2 MONITOR Channel
IOM-2 MONITOR Channel
Device
Slave
MONITOR Handler
MONITOR Handler
µC
Layer 1
Layer 1
PEB 3081
PEF 3081
3086_08
2000-09-27

Related parts for PEB3081FV14XP