8.2.14 enable profile
1
1
1
1
1
1
8-16
- PFU_COND: NO_VAL_INST_FETCH_PC cond_abort_mode=0
- PFU_PC: 0x00f800 pf_addr:0x00f800
- PFU_AGN: p0:0, c0:0, a0:0, p1:0, c1:0, a1=0
- PFU_cl_unv[1 0 0 0 0 0 0 0] cl_disc_unv[1 0 0 0 0 0 0 0]
- PFU C:d1=-1, C:d2=-1, C:d3=-1, C:d4=-1, N:d1=0, N:d2=0, N:d3=0, N:d4=0
Grouping Rule: none (0 instructions in G stage).
Format –
Example –
This command enables a predefined trace type. Run-time traces
generate text output representing the state of the architecture on a cycle-
by-cycle basis. There are four types of predefined runtime tracing:
ZSP SDK Cycle-Accurate Simulator
Copyright © 1999-2003 by LSI Logic Corporation. All rights reserved.
enable break breakpoint_number
zsim{32} enable break 1
du
Displays information from the data unit of the ZSP400 architecture,
such as data cache hits and the du_imem_read signal. This is not
valid for G2.
iu
Displays information from the instruction unit, such as instruction
cache hits and instruction fetch signal.
For zsim400, the output looks like:
cycle# -
cycle# -
For zsimg2, the output looks like:
The first column displays the cycle count. The PFU_COND line displays
the condition of the PFU state machine and the mode it operates in.
The possible states are shown in
cond_abort_mode=1 means the PFU receives the reqi_cond_abort
signal from the memory subsystem. The PFU_PC line displays the
current PC address coming from the ISU (Instruction Sequencing
Unit). The PFU_AGN line displays agn status for the loop awakening
logic. The next line shows the state of the cl_unv (cache-line
unavailable) and cl_disc_unv (cache-line discontinuity unavailable)
IU_IMEM_READ : address
ICACHE hits
: address
Table
8.6. The field