PEB 2466 H V2.2 Infineon Technologies, PEB 2466 H V2.2 Datasheet - Page 35

no-image

PEB 2466 H V2.2

Manufacturer Part Number
PEB 2466 H V2.2
Description
IC SICOFI-4 SGL CHIP CMOS MQFP64
Manufacturer
Infineon Technologies
Series
SICOFI®r
Datasheet

Specifications of PEB 2466 H V2.2

Function
CODEC Filter
Interface
PCM, SPI
Number Of Circuits
4
Voltage - Supply
5V
Current - Supply
26mA
Power (watts)
130mW
Operating Temperature
0°C ~ 70°C
Mounting Type
Surface Mount
Package / Case
64-QFP
Includes
Advanced On-Chip Functions, Digital Signal Processing (DSP) Technique, Level Metering, Tone Generators
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Other names
PEB2466HV2.2XT
PEB2466HV22NP
PEB2466HV22XP
SP000007516
SP000007517
4.2.18
The quality of Transhybrid-Balancing is very sensitive to deviations in gain, group delay,
and deviations inherent to the A/D- and D/A-converters, as well as to all external
components used on a linecard (SLIC, OP’s etc.).
Transhybrid loss test setup:
The SICOFI
analog output with the analog input. The programmable filters FRR, AR, FRX, AX are
by-passed. The IM-filter is disabled, (H(IM)=0). The balancing filter TH is enabled with
optimized coefficients for this configuration (
A 0 dBm0 sine wave signal with a frequency in the range of 300 Hz to 3400 Hz is applied
to the digital input. The signal levels of the resulting echo at the digital output will stay
below the values shown in Table 20.
Table 20
Hardware Reference Manual
Input Frequency
2500 Hz
3000 Hz
3400 Hz
300 Hz
500 Hz
Transhybrid Loss
®
4-µC test loop “DLB-ANA” is selected (see Figure 34), which connects the
Transhybrid Loss
Symbol
THL
THL
THL
THL
THL
2500
3000
3400
300
500
Transhybrid Loss
min.
27
30
29
27
27
26
V
OUT
typ.
40
45
40
35
35
=
V
IN
).
Unit
dB
dB
dB
dB
dB
Operational Description
T
AGX = AGR = 0 dB;
typical variation of
amplitude:
delay:
A
= 25 C;
Test Condition
0.5 s.
V
0.15 dB
PEB 2466
DD
PEF 2466
2001-02-20
= 5 V

Related parts for PEB 2466 H V2.2