SC16C652BIB48,151 NXP Semiconductors, SC16C652BIB48,151 Datasheet - Page 16

IC UART DUAL W/FIFO 48-LQFP

SC16C652BIB48,151

Manufacturer Part Number
SC16C652BIB48,151
Description
IC UART DUAL W/FIFO 48-LQFP
Manufacturer
NXP Semiconductors
Type
IrDAr
Datasheet

Specifications of SC16C652BIB48,151

Number Of Channels
2, DUART
Package / Case
48-LQFP
Features
2 Channels
Fifo's
32 Byte
Voltage - Supply
2.5V, 3.3V, 5V
With Auto Flow Control
Yes
With Irda Encoder/decoder
Yes
With False Start Bit Detection
Yes
With Modem Control
Yes
With Cmos
Yes
Mounting Type
Surface Mount
Data Rate
5 Mbps
Supply Voltage (max)
5.5 V
Supply Voltage (min)
2.25 V
Supply Current
4.5 mA
Maximum Operating Temperature
+ 85 C
Minimum Operating Temperature
- 40 C
Mounting Style
SMD/SMT
Operating Supply Voltage
2.5 V or 3.3 V or 5 V
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Lead Free Status / RoHS Status
Lead free / RoHS Compliant, Lead free / RoHS Compliant
Other names
568-3276
935274409151
SC16C652BIB48-S

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
SC16C652BIB48,151
Manufacturer:
NXP Semiconductors
Quantity:
10 000
Philips Semiconductors
SC16C652B_4
Product data sheet
7.1 Transmit (THR) and Receive (RHR) Holding Registers
7.2 Interrupt Enable Register (IER)
The serial transmitter section consists of an 8-bit Transmit Hold Register (THR) and
Transmit Shift Register (TSR). The status of the THR is provided in the Line Status
Register (LSR). Writing to the THR transfers the contents of the data bus (D7 to D0) to the
TSR and UART via the THR, providing that the THR is empty. The THR empty flag in the
LSR will be set to a logic 1 when the transmitter is empty or when data is transferred to the
TSR. Note that a write operation can be performed when the THR empty flag is set
(logic 0 = at least one byte in FIFO/THR, logic 1 = FIFO/THR empty).
The serial receive section also contains an 8-bit Receive Holding Register (RHR) and a
Receive Serial Shift Register (RSR). Receive data is removed from the SC16C652B and
receive FIFO by reading the RHR. The receive section provides a mechanism to prevent
false starts. On the falling edge of a start or false start bit, an internal receiver counter
starts counting clocks at the 16 clock rate. After 7
shifted to the center of the start bit. At this time the start bit is sampled, and if it is still a
logic 0 it is validated. Evaluating the start bit in this manner prevents the receiver from
assembling a false character. Receiver status codes will be posted in the LSR.
The Interrupt Enable Register (IER) masks the interrupts from receiver ready, transmitter
empty, line status and modem status registers. These interrupts would normally be seen
on the INTA, INTB output pins.
Table 10:
Bit
7
6
5
4
3
2
Symbol Description
IER[7]
IER[6]
IER[5]
IER[4]
IER[3]
IER[2]
Interrupt Enable Register bits description
CTS interrupt.
RTS interrupt.
Xoff interrupt.
Sleep mode.
Modem Status Interrupt. This interrupt will be issued whenever there is a modem
status change as reflected in MSR[3:0].
Receive Line Status interrupt. This interrupt will be issued whenever a receive
data error condition exists as reflected in LSR[4:1].
logic 0 = disable the CTS interrupt (normal default condition)
logic 1 = enable the CTS interrupt. The SC16C652B issues an interrupt when
the CTS pin transitions from a logic 0 to a logic 1.
logic 0 = disable the RTS interrupt (normal default condition)
logic 1 = enable the RTS interrupt. The SC16C652B issues an interrupt when
the RTS pin transitions from a logic 0 to a logic 1.
logic 0 = disable the software flow control, receive Xoff interrupt (normal
default condition)
logic 1 = enable the software flow control, receive Xoff interrupt.
logic 0 = disable Sleep mode (normal default condition)
logic 1 = enable Sleep mode
logic 0 = disable the modem status register interrupt (normal default condition)
logic 1 = enable the modem status register interrupt
logic 0 = disable the receiver line status interrupt (normal default condition)
logic 1 = enable the receiver line status interrupt
Rev. 04 — 1 September 2005
Dual UART with 32-byte FIFOs and IrDA encoder/decoder
1
2
clocks, the start bit time should be
© Koninklijke Philips Electronics N.V. 2005. All rights reserved.