AD9286 Analog Devices, AD9286 Datasheet - Page 22

no-image

AD9286

Manufacturer Part Number
AD9286
Description
8-Bit, 500 MSPS, 1.8 V Analog-to-Digital Converter (ADC)
Manufacturer
Analog Devices
Datasheet

Specifications of AD9286

Resolution (bits)
8bit
# Chan
2
Sample Rate
500MSPS
Interface
Par
Analog Input Type
Diff-Bip,Diff-Uni
Ain Range
2 V p-p
Adc Architecture
Pipelined
Pkg Type
CSP
AD9286
MEMORY MAP
READING THE MEMORY MAP REGISTER TABLE
Each row in the memory map register table (see Table 13) has
eight bit locations. The memory map is roughly divided into
three sections: the chip configuration registers (Address 0x00
to Address 0x02), the device index and transfer registers
(Address 0x05 and Address 0xFF), and the program registers
(Address 0x08 to Address 0x38).
Table 13 documents the default hexadecimal value for each
hexadecimal address shown. The column with the heading Bit 7
(MSB) is the start of the default hexadecimal value given. For
more information on this function and others, see the
Application Note, Interfacing to High Speed ADCs via SPI. This
document details the functions controlled by Register 0x00 to
Register 0xFF.
Open Locations
All address and bit locations that are not included in the SPI
map are not currently supported for this device. Unused bits of
a valid address location should be written with 0s. Writing to these
locations is required only when part of an address location is
open. If the entire address location is open, it is omitted from the
SPI map (for example, Address 0x13) and should not be written.
Default Values
After the AD9286 is reset, critical registers are loaded with
default values. The default values for the registers are given
in the memory map register table (see Table 13).
AN-877
Rev. A | Page 22 of 28
Logic Levels
An explanation of logic level terminology follows:
Transfer Register Map
Address 0x08 to Address 0x38 are shadowed. Writes to these
addresses do not affect part operation until a transfer command
is issued by writing 0x01 to Address 0xFF, setting the transfer bit.
Setting the transfer bit allows these registers to be updated
internally and simultaneously. The internal update takes place
when the transfer bit is set, and then the bit autoclears.
Channel-Specific Registers
Some channel setup functions can be programmed differently
for each channel. In these cases, channel address locations are
internally duplicated for each channel. These registers and bits
are designated in the memory map register table as local. These
local registers and bits can be accessed by setting the appropriate
Channel 1 (Bit 0) or Channel 2 (Bit 1) bits in Register 0x05.
If both bits are set, the subsequent write affects the registers of
both channels. In a read cycle, set only Channel 1 or Channel 2
to read one of the two registers. If both bits are set during an
SPI read cycle, the part returns the value for Channel 1.
Registers and bits designated as global in the memory map
register table affect the entire part or the channel features for
which independent settings are not allowed between channels.
The settings in Register 0x05 do not affect the global registers
and bits.
“Bit is set” is synonymous with “bit is set to Logic 1” or
“writing Logic 1 for the bit. ”
“Bit is cleared” is synonymous with “bit is set to Logic 0” or
“writing Logic 0 for the bit. ”

Related parts for AD9286