7.11. Power Level Definition
7.11.1. Power Level
6 level modes are defined they are in order of Maximum Power consumption to Minimum Power Consumption:
1. Normal Mode On (full display), Idle Mode Off, Sleep Out.
2. Partial Mode On, Idle Mode Off, Sleep Out.
3. Normal Mode On (full display), Idle Mode On, Sleep Out.
4. Partial Mode On, Idle Mode On, Sleep Out.
5. Sleep In Mode
6. Power Off Mode
Note: Transition between modes 1-5 is controllable by MCU commands. Mode 6 is entered only
when both Power supplies are removed.
© ORISE Technology Co., Ltd.
Proprietary & Confidential
In this mode, the display is able to show maximum 262,144 colors.
In this mode part of the display is used with maximum 262,144 colors.
In this mode, the full display area is used but with 8 colors.
In this mode, part of the display is used but with 8 colors.
In this mode, the DC: DC converter, Internal oscillator and panel driver circuit are stopped. Only the MCU interface and memory works
with VDDIO power supply. Contents of the memory are safe.
In this mode, both VDD and VDDIO are removed.