10.1.2.13. Fan Output PWM Polarity Control (FOPPC)
Location: FOPPC - Bank 2 Address 38
Reset:
10.1.2.14. FANIN Target Speed (FTS)
W83795G/ADG will try to tune relative fan output to keep the fan speed of target. The default target
speed for FANIN tachometer is 6000h.
Location:
F1TSH - Bank 2 Address 40
F1TSL - Bank 2 Address 41
F2TSH - Bank 2 Address 42
F2TSL - Bank 2 Address 43
F3TSH - Bank 2 Address 44
F3TSL - Bank 2 Address 45
F4TSH - Bank 2 Address 46
F4TSL - Bank 2 Address 47
F5TSH - Bank 2 Address 48
F5TSL - Bank 2 Address 49
F6TSH - Bank 2 Address 4A
F6TSL - Bank 2 Address 4B
F7TSH - Bank 2 Address 4C
F7TSL - Bank 2 Address 4D
F8TSH - Bank 2 Address 4E
DEFAULT
7-0
NAME
BIT
7-0
BIT
In Fan Speed Cruise
Init Reset (CR01.Bit7) is set,
3VSB Rising,
3VDD Rising @ RST_VDD_MD (CR01.Bit5) set,
SYSRSTIN# Falling @ SYSRST_MD (CR01.Bit6) set.
FanStopTime – control the FANCTL1-FANCTL8 fan stop time from FONV (Fan Output
Nonstop Value) to the off state.
Unit in 0.1sec. Ranges from 0.1sec to 25.5sec.
If set to 0, the fan will never stop.
FANCTL3-FANCTL8 functions are not for W83795ADG.
F8POL – F1POL: control FANCTL8 - FANCTL1 PWM output polarity.
0 = Low active. PWM is controlled by negative duty cycle.
1 = High active. (Default). PWM is controlled by positive duty cycle.
FANCTL3-FANCTL8 functions are not for W83795ADG.
F8POL
7
F7POL
TM
HEX
HEX
HEX
HEX
HEX
HEX
HEX
HEX
HEX
HEX
HEX
HEX
HEX
HEX
HEX
6
mode, each FANIN tachometer has to have a target fan speed. The
F6POL
HEX
5
FOPPC
- 111 –
F5POL
DESCRIPTION
4
FF
HEX
F4POL
3
F3POL
2
W83795G/ADG
F2POL
1
Revision 1.41
Aug/2/2010
F1POL
0