TEMP CTRL2 – Temperature Monitoring Control Register
Location: Bank 0 Address 05
Default Value: 55
FANIN CTRL1 – FANIN Monitoring Control Register
Location: Bank 0 Address 06
Default Value: FF
BIT
1-0
BIT
7-6
5-4
3-2
1-0
BIT
7
11
TR5/VSEN12_MD – TR5/VSEN12 monitoring selection mode.
0X
10
11
TD4/TR4/VDSEN17_MD – TD4/TR4/VDSEN17 monitoring selection mode. Note that it
needs refer the application to set register.
00
01
10
11
TD3/TR3/VDSEN16_MD – TD3/TR3/VDSEN16 monitoring selection mode. Note that it
needs refer the application to set register.
00
01
10
11
TD2/TR2/VDSEN15_MD – TD2/TR2/VDSEN15 monitoring selection mode. Note that it
needs refer the application to set register.
00
01
10
11
TD1/TR/VDSEN14_MD – TD1/TR1/VDSEN14 monitoring selection mode. Note that it
needs refer the application to set register.
00
01
10
11
EN_FANIN8 – Enable FANIN8 monitoring.
BIN
BIN
BIN
BIN
BIN
BIN
BIN
BIN
BIN
BIN
BIN
BIN
BIN
BIN
BIN
BIN
BIN
BIN
BIN
BIN
= Enable TR6 thermistor temperature monitoring (Default)
= Enable VSEN12 voltage monitoring
= Enable TR5 thermistor temperature monitoring (Default)
= Disable TD4/TR4/VDSEN17 monitoring
= Enable TD4 thermal diode temperature monitoring (Default)
= Enable VDSEN17 different mode voltage monitoring
= Enable TR4 thermistor temperature monitoring
= Disable TD3/TR3/VDSEN16 monitoring
= Enable TD3 thermal diode temperature monitoring (Default)
= Enable VDSEN16 different mode voltage monitoring
= Enable TR3 thermistor temperature monitoring
= Disable TD2/TR2/VDSEN15 monitoring
= Enable TD2 thermal diode temperature monitoring (Default)
= Enable VDSEN15 different mode voltage monitoring
= Enable TR2 thermistor temperature monitoring
= Disable TD1/TR1/VDSEN14 monitoring
= Enable TD1 thermal diode temperature monitoring (Default)
= Enable VDSEN14 different mode voltage monitoring
= Enable TR1 thermistor temperature monitoring
= Disable TR5/VSEN12 monitoring