A25L05PMF-50 AMICC [AMIC Technology], A25L05PMF-50 Datasheet - Page 25

no-image

A25L05PMF-50

Manufacturer Part Number
A25L05PMF-50
Description
8 Mbit, Low Voltage, Serial Flash Memory With 50 MHz SPI Bus Interface
Manufacturer
AMICC [AMIC Technology]
Datasheet
Lead Temperature during Soldering (Note 1)
Absolute Maximum Ratings*
Storage Temperature (TSTG) . . . . . . . . . . . . . -65°C to + 150°C
Input and Output Voltage (with respect to Ground) (VID) . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . -0.6V to +4.0V
Supply Voltage (VCC) . . . . . . . . . . . . . . . . . . . . . -0.6V to +4.0V
Electrostatic Discharge Voltage (Human Body model) (VESD)
(Note 2) . . . . . . . . . . . . . . . . . . . . . . . . . . . . -2000V to 2000V
Notes:
1. Compliant with JEDEC Std J-STD-020B (for small body,
2. JEDEC Std JESD22-A114A (C1=100 pF, R1=1500Ω, R2=500
DC AND AC PARAMETERS
This section summarizes the operating and measurement
conditions, and the DC and AC characteristics of the device.
The parameters in the DC and AC Characteristic tables that
follow
Table 7. Operating Conditions
Table 8. Data Retention and Endurance
Note: 1. This is preliminary data
Table 9. Capacitance
Note: Sampled only, not 100% tested, at T
PRELIMINARY
Erase/Program Cycles
Data Retention
C
C
Ω)
Symbol
Sn-Pb or Pb assembly).
Symbol
OUT
IN
V
T
CC
A
Parameter
are
derived
Output Capacitance (Q)
Input Capacitance (other pins)
Supply Voltage
Ambient Operating Temperature
(May 2005, Version 0.0)
from
Parameter
At 85°C
At 85°C
tests
performed
Parameter
A
Condition
=25°C and a frequency of 33 MHz.
under
V
V
OUT
IN
= 0V
= 0V
Test Condition
the
24
*Comments
Stressing the device above the rating listed in the Absolute
Maximum Ratings" table may cause permanent damage to the
device. These are stress ratings only and operation of the
device at these or any other conditions above those indicated in
the Operating sections of this specification is not implied.
Exposure to Absolute Maximum Rating conditions for extended
periods may affect device reliability. Refer also to the AMIC
SURE Program and other relevant quality documents.
Measurement Conditions summarized in the relevant tables.
Designers should check that the operating conditions in their
circuit match the measurement conditions when relying on the
quoted parameters.
Min.
Min.
Min.
–40
2.7
100,000
AMIC Technology Corp.
Max.
20
Max.
Max.
3.6
85
8
6
Cycles per sector
A25L80P
Years
Unit
Unit
Unit
°C
pF
pF
V

Related parts for A25L05PMF-50