MC68306 Motorola, MC68306 Datasheet - Page 59

no-image

MC68306

Manufacturer Part Number
MC68306
Description
Integrated EC000 Processor
Manufacturer
Motorola
Datasheet

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
MC68306AG16B
Manufacturer:
Freescale Semiconductor
Quantity:
10 000
Part Number:
MC68306AG20B
Manufacturer:
Freescale Semiconductor
Quantity:
10 000
Part Number:
MC68306CEH16B
Manufacturer:
Freescale Semiconductor
Quantity:
10 000
Part Number:
MC68306EH16B
Manufacturer:
DATEL
Quantity:
87
Part Number:
MC68306EH16B
Manufacturer:
Freescale Semiconductor
Quantity:
10 000
Part Number:
MC68306EH16BR2
Manufacturer:
Freescale Semiconductor
Quantity:
10 000
Part Number:
MC68306FC16
Manufacturer:
FREESCALE
Quantity:
12 388
Part Number:
MC68306FC16
Manufacturer:
MOTOROLA
Quantity:
672
Part Number:
MC68306FC16A
Manufacturer:
IDT
Quantity:
924
Part Number:
MC68306FC16A
Manufacturer:
MOTOROLA
Quantity:
1 045
Part Number:
MC68306FC16A
Manufacturer:
MOTOROLA/摩托罗拉
Quantity:
20 000
Part Number:
MC68306FC16B
Manufacturer:
MOTOROLA/摩托罗拉
Quantity:
20 000
S0
S2
S4
S6
S0
S2
S4
S6
CLK
FC2–FC0
A31–A1
AS
LDS/UDS
R/W
DTACK
D15–D0
HALT
READ
HALT
READ
Figure 3-26. Halt Operation Timing Diagram
The single-step mode is derived from correctly timed transitions of HALT. HALT is negated
to allow the processor to begin a bus cycle, then asserted to enter the halt mode when the
cycle completes. The single-step mode proceeds through a program one bus cycle at a
time for debugging purposes. The halt operation and the hardware trace capability allow
tracing of either bus cycles or instructions one at a time. These capabilities and a software
debugging package provide total debugging flexibility.
3.4.4 Double Bus Fault
When a bus error exception occurs, the processor begins exception processing by
stacking information on the supervisor stack. If another bus error occurs during exception
processing (i.e., before execution of another instruction begins) the processor halts and
asserts HALT. This is called a double bus fault. Only an external reset operation can
restart a processor halted due to a double bus fault.
A retry operation does not initiate exception processing; a bus error during a retry
operation does not cause a double bus fault. The processor can continue to retry a bus
cycle indefinitely if external hardware requests.
A double bus fault occurs during a reset operation when a bus error occurs while the
processor is reading the vector table (before the first instruction is executed). The reset
operation is described in the following paragraph.
3.5 RESET OPERATION
RESET is asserted externally for the initial processor reset. Subsequently, the signal can
be asserted either externally or internally (executing a RESET instruction).
MOTOROLA
MC68306 USER'S MANUAL
3- 27