TLE6361G Infineon Technologies, TLE6361G Datasheet - Page 13

IC PS SYSTEM MULTI VOLT PDSO-36

TLE6361G

Manufacturer Part Number
TLE6361G
Description
IC PS SYSTEM MULTI VOLT PDSO-36
Manufacturer
Infineon Technologies
Type
Step-Down (Buck)r
Datasheet

Specifications of TLE6361G

Internal Switch(s)
Yes
Synchronous Rectifier
No
Number Of Outputs
4
Voltage - Output
5.4 ~ 6.05 V
Current - Output
1.5A
Frequency - Switching
370kHz
Voltage - Input
5.5 ~ 60 V
Operating Temperature
-40°C ~ 150°C
Mounting Type
Surface Mount
Package / Case
DSO-36
Output Voltage
5.5 V
Output Current
1.5 A
Input Voltage Max
60 V
Maximum Operating Temperature
+ 150 C
Minimum Operating Temperature
- 40 C
Mounting Style
SMD/SMT
Operating Temperature Range
- 40 C to + 150 C
Output Voltage Tolerance
+/- 10 %
Lead Free Status / RoHS Status
Contains lead / RoHS non-compliant
Power - Output
-
Lead Free Status / Rohs Status
Lead free / RoHS Compliant
Other names
SP000013297
TLE6361GNT
TLE6361GT

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
TLE6361G
Manufacturer:
INFINEON
Quantity:
5 510
Part Number:
TLE6361G
Manufacturer:
INFINEON/英飞凌
Quantity:
20 000
Q_LDO1 has decreased below 3.3V (max.) the default settings are valid, means the
64ms delay time. If the voltage on Q_LDO1 during sleep or power off mode was kept
above 3.3V the delay time set by the last SPI command is valid.
Figure 5 Undervoltage reset timing
2.7
A RAM good flag will be set within the SPI status word when the Q_LDO1 voltage drops
below 2.3V. A second one will be set if Q_LDO2 drops below typical 1.4V. Both RAM
good flags can be read after power up to determine if a cold or warm start needs to be
processed. Both RAM good flags will be reset after each SPI cycle.
2.8
An hardware error pin indicates any fault conditions on the chip. It should be connected
to an interrupt input of the microcontroller. A low signal indicates an error condition. The
microcontroller can read the root cause of the error by reading the SPI register.
2.9
The on board window watchdog for supervision of the µC works in combination with the
SPI. The window watchdog logic is triggered when CS is low and Bit WD-Trig in the SPI
command word is set to “1”. The watchdog trigger is recognized with the low to high
transition of the CS signal. To allow reading the SPI at any time without getting a reset
due to misinterpretation the WD-Trig bit has to be set to “0” to avoid false trigger
conditions. To disable the window watchdog the WD-OFF bits need to be set to “010”.
Data Sheet, Rev. 2.0
V
V
Q_LDOx
FB/L_IN
RAM good flag
ERR Pin
Window Watchdog
V
Rx
t
RES
shutdown
thermal
t
rr
t
RES
voltage
under
13
t
< t
RES
rr
over
load
t
RES
TLE 6361 G
V
RTH,Q_LDOx
t
t
t
2005-03-01

Related parts for TLE6361G