Z8FMC160100KIT Zilog, Z8FMC160100KIT Datasheet - Page 143

KIT DEV FOR Z8 ENCORE Z8FMC16100

Z8FMC160100KIT

Manufacturer Part Number
Z8FMC160100KIT
Description
KIT DEV FOR Z8 ENCORE Z8FMC16100
Manufacturer
Zilog
Series
Z8 Encore! MC™r

Specifications of Z8FMC160100KIT

Main Purpose
Power Management, Motor Control
Embedded
Yes, MCU, 8-Bit
Utilized Ic / Part
Z8FMC16100
Primary Attributes
3-Ph DC Motors
Secondary Attributes
Graphic User Interface
Processor To Be Evaluated
Z8FMC16100
Data Bus Width
8 bit
Interface Type
USB
For Use With
269-4664 - KIT ACC OPTO-ISO USB SMART CABLE269-4661 - KIT ACC ETHERNET SMART CABLE269-4539 - KIT ACCESSORY USB SMART CABLE
Lead Free Status / RoHS Status
Contains lead / RoHS non-compliant
Other names
269-3639
Table 70. LIN-UART Mode Select and Status Register (U0MDSTAT)
PS024613-0910
BITS
FIELD
RESET
R/W
ADDR
LIN-UART Mode Select and Status Register
R/W
7
0
The LIN-UART Mode Select and Status register
status bits. A more detailed discussion of each bit follows the table.
MSEL—Mode Select
This R/W field determines which control register is accessed when performing a write or
read to the Uart Control 1 register address. This field also determines which status is
returned in the ModeStatus field when reading this register.
000 = Multiprocessor and normal UART control/status
001 = Noise Filter control/status
010 = LIN Protocol control/status
011–110: reserved
111 = LIN-UART Hardware Revision (allows hardware revision to be read in the Mode
Status field)
Mode Status. This read-only field returns status corresponding to the mode selected by
MSEL
000: Multiprocessor and normal UART mode status =
001: Noise Filter status =
010: LIN mode status =
011–110: reserved =
111: LIN-UART hardware revision
MULTIPROCESSOR Mode Status field (MSEL = 000B)
NE—Noise Event. This bit is asserted if digital noise is detected on the receive data line
while the data is sampled (center of bit time). If this bit is set, it does not mean that the
receive data is corrupted (though it may be in extreme cases), just that one or more of the
noise filter data samples near the center of the bit time did not match the average data
value.
NEWFRM—Status bit denoting the start of a new frame. Reading the LIN-UART Receive
Data register resets this bit to 0.
as follows:
MSEL
R/W
6
0
{0, 0, 0, 0, 0}
R/W
5
0
{NE, RxBreakLength[3:0]}
{NE, 0,0,0,0}
R
4
0
F44H
R
3
0
LIN-UART Mode Select and Status Register
(Table
Z8FMC16100 Series Flash MCU
Mode Status
{NE, 0, 0, NEWFRM, MPRX}
R
2
0
70) contains mode select and
Product Specification
R
1
0
R
0
0
131