EP9315-CBZ Cirrus Logic Inc, EP9315-CBZ Datasheet - Page 531

IC ARM9 SOC ENH UNIV 352PBGA

EP9315-CBZ

Manufacturer Part Number
EP9315-CBZ
Description
IC ARM9 SOC ENH UNIV 352PBGA
Manufacturer
Cirrus Logic Inc
Series
EP9r
Datasheets

Specifications of EP9315-CBZ

Core Size
16/32-Bit
Core Processor
ARM9
Speed
200MHz
Connectivity
EBI/EMI, EIDE, Ethernet, I²C, IrDA, Keypad/Touchscreen, PCMCIA, SPI, UART/USART, USB
Peripherals
AC'97, DMA, I&sup2:S, LCD, LED, MaverickKey, POR, PWM, WDT
Number Of I /o
16
Program Memory Type
ROMless
Ram Size
32K x 8
Voltage - Supply (vcc/vdd)
1.65 V ~ 3.6 V
Data Converters
A/D 8x12b
Oscillator Type
External
Operating Temperature
0°C ~ 70°C
Package / Case
352-BGA
Controller Family/series
(ARM9)
No. Of I/o's
16
Cpu Speed
200MHz
No. Of Timers
5
Digital Ic Case Style
BGA
Supply Voltage Range
1.65V To 1.94V, 3V To 3.6V
Embedded Interface Type
SPI
Rohs Compliant
Yes
Processor Series
EP93xx
Core
ARM920T
Data Bus Width
32 bit
3rd Party Development Tools
MDK-ARM, RL-ARM, ULINK2
Development Tools By Supplier
EDB9315A-Z
Case
BGA
Dc
06+
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
For Use With
598-1144 - KIT DEVELOPMENT EP9315 ARM9
Eeprom Size
-
Program Memory Size
-
Lead Free Status / Rohs Status
 Details
Other names
598-1139

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
EP9315-CBZ
Manufacturer:
Cirrus Logic Inc
Quantity:
10 000
Part Number:
EP9315-CBZ
Manufacturer:
ALTERA
0
Part Number:
EP9315-CBZ
Manufacturer:
CIRRUS
Quantity:
20 000
Company:
Part Number:
EP9315-CBZ
Quantity:
48
DS785UM1
14.4.1 Overview of HDLC Modes
14.4.2 Selecting HDLC Modes
HDLC may operate in one of two basic modes, synchronous or asynchronous. Most
configuration options affect both modes identically. Setting the UART1HDLCCtrl.SYNC bit
selects synchronous mode and clearing it selects asynchronous mode. In asynchronous
mode, each byte is transmitted using standard UART protocol framing (that is, start bit, data,
parity, stop bit(s)). In synchronous mode, UART framing is bypassed.
The synchronous HDLC bit stream may be either a NRZ or Manchester encoded. In NRZ
mode, both the transmitter and receiver may be synchronized to either an external or internal
clock running at one cycle per bit period. The transmitter and receiver may operate
independently in any of the four modes:
In the first NRZ mode, the data stream does not contain an explicit or implicit clock, so
synchronization between an HDLC transmitter and receiver cannot be guaranteed. A data bit
value of “1” is encoded as a one in the bit stream, and a value of “0” as a zero.
The second mode, Manchester encoding, combines the HDLC data and clock into a single bit
stream. In Manchester encoding, a transition always occurs in the middle of a transmitted bit
and the value after this transition is the actual value of the bit. That is, a “0” bit is represented
by a transition from high to low, and a “1” bit by a transition from low to high. Because a
transition always occurs in the middle of a bit, the receiver can always extract the proper data
after a suitable period of synchronization, provided the signal quality is good.
The third and fourth modes utilize NRZ encoding of the data accompanied by a separate
clock signal. The period of the clock signal is one bit period. When using an internal clock, the
HDLC transmitter generates a clock such that the data is stable at the clock’s rising edge.
Hence, an external receiver may sample each data bit at the rising edge of the clock. The
internal receiver will also use the same clock to sample input data if programmed to do so.
The internal transmitter and/or receiver may also synchronize to an external, rather than
internal, clock. The internal receiver gets this clock along with the incoming HDLC data,
allowing it to always sample bits at the right time. In addition, the internal transmitter will
synchronize the data it transmits to this clock if programmed to do so. The transmitter will
insure that its data is valid before the rising edge of the clock, and the receiver expects the
same of the incoming bit stream.
By default, HDLC is NRZ-encoded. Set bit UART1HDLCCtrl.TXENC to force Manchester
encoding in the transmitter, and set bit UART1HDLCCtrl.RXENC to make the receiver expect
Manchester encoding.
• Simple NRZ mode
• Manchester encoded
• NRZ mode with an internal clock
• NRZ mode with an external clock