LIS3LV02DL STMicroelectronics, LIS3LV02DL Datasheet - Page 34

Board Mount Accelerometers MEMS INERTIAL SENSOR

LIS3LV02DL

Manufacturer Part Number
LIS3LV02DL
Description
Board Mount Accelerometers MEMS INERTIAL SENSOR
Manufacturer
STMicroelectronics
Datasheet

Specifications of LIS3LV02DL

Sensing Axis
X, Y, Z
Acceleration
2 g, 6 g
Digital Output - Number Of Bits
12 bit, 16 bit
Supply Voltage (max)
3.6 V
Supply Voltage (min)
2.16 V
Supply Current
0.65 mA
Maximum Operating Temperature
+ 85 C
Minimum Operating Temperature
- 40 C
Digital Output - Bus Interface
I2C, SPI
Sensitivity
1024 LSB/g
Package / Case
LGA-16
Output Type
Digital
Acceleration Range
±2g, ±6g
No. Of Axes
3
Interface Type
I2C, SPI
Sensitivity Per Axis
1024LSB / G
Sensor Case Style
LGA
No. Of Pins
16
Supply Voltage Range
2.16V To 3.6V
Rohs Compliant
Yes
Lead Free Status / RoHS Status
Lead free / RoHS Compliant

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
LIS3LV02DL
Manufacturer:
ST
0
Part Number:
LIS3LV02DL
Manufacturer:
ST
Quantity:
20 000
Company:
Part Number:
LIS3LV02DL
Quantity:
2 940
Part Number:
LIS3LV02DL-TR
Manufacturer:
ST
0
Part Number:
LIS3LV02DL@@@@
Manufacturer:
ST
0
Part Number:
LIS3LV02DLTR
Manufacturer:
ST
0
Register description
7.10
7.11
7.12
34/48
CTRL_REG3 (22h)
Table 34.
Table 35.
FDS bit enables (FDS=1) or bypass (FDS=0) the high pass filter in the signal chain of the
sensor.
CFS1, CFS0 bits defines the coefficient Hpc to be used to calculate the -3dB cut-off
frequency of the high pass filter:
HP_FILTER_RESET (23h)
Dummy register. Reading at this address zeroes instantaneously the content of the internal
high pass-filter. Read data is not significant.
STATUS_REG (27h)
Table 36.
Table 37.
ECK
HPDD
HPFF
FDS
CFS1, CFS0
ZYXOR
ZOR
YOR
XOR
ECK
ZYXOR
Register (22h)
Register description (22h)
Register (27h)
Register description (27h)
HPDD
External Clock. Default value: 0
(0: clock from internal oscillator; 1: clock from external pad)
High Pass filter enabled for Direction Detection. Default value: 0
(0: filter bypassed; 1: filter enabled)
High Pass filter enabled for Free-Fall and Wake-Up. Default value: 0
(0: filter bypassed; 1: filter enabled)
Filtered Data Selection. Default value: 0
(0: internal filter bypassed; 1: data from internal filter)
High-pass filter Cut-off Frequency Selection. Default value: 00
(00: Hpc=512
01: Hpc=1024
10: Hpc=2048
11: Hpc=4096)
X, Y and Z axis Data Overrun
Z axis Data Overrun
Y axis Data Overrun
X axis Data Overrun
ZOR
HPFF
YOR
f
cutoff
FDS
XOR
=
0.318
-------------- -
Hpc
ZYXDA
res
ODRx
---------------- -
res
2
ZDA
CFS1
YDA
LIS3LV02DL
CFS0
XDA

Related parts for LIS3LV02DL