GFL631T-3 INSTRUMENT TRANSFORMER, GFL631T-3 Datasheet - Page 38

GROUND FAULT CURENT

GFL631T-3

Manufacturer Part Number
GFL631T-3
Description
GROUND FAULT CURENT
Manufacturer
INSTRUMENT TRANSFORMER
Datasheet

Specifications of GFL631T-3

Accuracy
15%
Current Measuring Range Ac
30A To 360A
32
the trip capacitor, giving an output trip voltage. The charge stored in these capacitors is available between the ‘+’ and “ COMMON ” terminals for breaker trip
coil operation. The half wave rectif ication circuitry provides the advantage of maintaining a common neutral connection from input while still maintaining the
charge in the the trip capacitor after control power is lost .
involved, energy for the trip coil operation is immediately available with the loss of control power. When the control power returns, the capacitor automatically
charges to supply energy for the next trip coil.
Capacitor Trip Device
Model CTD
APPLICATION:
Provides a source of
energy for circuit breaker
and switch trip coil
operation during a loss
of AC control voltage.
Nominal 120 Volts ac , or 240 Volts ac is is applied between the “ INPUT ” and “ COMMON ” terminals. This voltage is half wave rectif ied and applied across
The capacitor is continuously charged when control power is available, providing energy for normal trip coil operation. Because mechanical relays are not
These devices are protected against inadvertent output short circuit , inductive kickback from the trip coil, and input line voltage surges.
-
4
USA, Canada, Asia, Latin America
Please refer to our website www.GEMultilin.com for more detailed contact information
e-mail: sales.multilin@ge.com
NORMAL INPUT:
120 VAc or 240 VAC
FREQUENCY:
DC to
Fax: +1-905-201-2455
Tel: +1-800-547-8629
400Hz.
Specif ications
Normal Output Voltage:
CTD-4-120: 120 V,
CTD-4-240: 240 V
Max. Input Voltage:
CTD-4-120: 140Vac,CTD-4-240: 280Vac
Available energy trip capacitor fully
charged at normal input voltage:
CTD-4-120: 64 joules + 20% @ 25
CTD-4-240: 57 joules + 20% @ 25
Normal Output Voltage:
CTD-4-120: 169 Volts DC,
CTD-4-240: 338 Volts DC
Approx charge time to 90% at 25
CTD-4-120: 1.4S, CTD-4-240: 570mS
Capacitance:
CTD-4-120: 4500 uF +20% @ 25
CTD-4-240: 990 uF+ 20% @ 25
Temp. influence on cap.:
-10%@ -30
o
C/ +5%@+60
e-mail: gemultilin.euro@ge.com
Europe, Middle East , Africa
o
C
Fax: +34-94-485-88-45
Tel: +34-94-485-88-00
U L
®
o
o
C
C
o
o
o
C
C
C
IND. CONT. EQUIP.
LISTED
Operating temperature range:
-30
Storage temp range:
-50
Short Circuit Protection:
Continuous
Mounting:
Input Surge Protection:
MOV protected to 65 joules puls e surge
Vertical or horizontal
o
o
C to 60
C to 80
C
o
o
C
C
U L
®
FILE NO.
E103039
Electronic Products

Related parts for GFL631T-3