XTOB004CC1 EATON CUTLER HAMMER, XTOB004CC1 Datasheet - Page 144

Overload Relay

XTOB004CC1

Manufacturer Part Number
XTOB004CC1
Description
Overload Relay
Manufacturer
EATON CUTLER HAMMER
Datasheet

Specifications of XTOB004CC1

Overload Adjustment Current Min
2.4A
Overload Adjustment Current Max
4A
Coil Voltage Dc Max
220V
Contactor Direction
Non Reversing
Coil Voltage Vdc Nom
220V
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
34-144
34
Table 34-181. Undervoltage Release — Technical Data and
Specifications
Cross-sections
Main Contacts
Power Consumption
Table 34-182. Current Limiter
Figure 34-103. XTPB, XTPR 1- and 2-Pole Circuits with DC and
AC Current
Figure 34-104. Protection of PVC Insulated Cables Against Thermal
Overload at Short Circuit
The table indicates which minimum cable cross-sections are
protected by XTPR motor protective circuit breakers up to
their rated conditional short circuit current I q .
Description
Solid or flexible conductor with ferrule (mm
Solid or stranded (AWG)
Rated operational voltage, U e (V AC)
Rated operational voltage, U e (V DC)
Pick-up voltage, x U s
Drop-out voltage, x U s
Pick-up AC (VA)
Sealing AC (VA)
Description
Rated Impulse withstand Voltage (U imp ), V AC
Overvoltage Category/ Pollution Degree
Rated operational voltage, U e (V AC)
Rated interrupted current = Rated operational current
(l u = l e ) in amperes
IEC Contactors & Starters
XT IEC Power Control
Manual Motor Protectors
Min. Cross-Section Protected
380-415V, 50 Hz, Cu mm
4
2.5
I > I > I >
1
2 4 6
1.5
3 5
1
2
0.75
2
)
I > I > I >
1 3 5
2 4 6
Device
Type
XTPRP16BC1
XTPR6P3BC1
XTPR010BC1
XTPR016BC1
XTPR020BC1
XTPR025BC1
XTPR016DC1
XTPR025DC1
XTPR032DC1
XTPR040DC1
XTPR050DC1
XTPR058DC1
XTPR063DC1
For more information visit: www.eaton.com
XTPAXUVR…
1 x (0.75 – 2.5)
2 x (0.75 – 2.5)
1 x (18 – 14)
2 x (18 – 14)
42 – 480
24 – 250
0.85 – 1.1
0.7 – 0.35
5
3
XTPAXCL
6000
III/3
690
63
Table 34-183. Shunt Release — Technical Data and Specifications
Cross-sections
Main Contacts
Power Consumption
Figure 34-105. Fuseless Installation with XTPR, Back-Up
Protection Diagrams
Description
Solid or flexible conductor with ferrule (mm
Solid or stranded (AWG)
Rated operational voltage, U e (V AC)
Rated operational voltage, U e (V DC)
AC Operating Range, x U s
DC Operating Range, x U s (intermittent operation 5s)
Pick-up AC (VA)
Sealing AC (VA)
Pick-up DC (VA)
Sealing DC (VA)
Back-up
protection
range
with XTPAXCL
Rated
short-circuit
breaking
capacity
range
Back-up
protection
range
with XTPAXCL
Rated
short-circuit
breaking
capacity
range
XTPR…B
XTPR…D
415V AC
415V AC
XTPR…B
XTPR…D
100
100
50
30
20
16
10
50
30
20
16
10
6
6
XTPR...B
Inherently
short-circuit-proof
0.16...
16...
2
)
25
XTPR...D + XTPAXCL
XTPR…D
Rated
Current
n [A]
32
40
1016 20 25
XTPAXSR __
1 x (0.75 – 2.5)
2 x (0.75 – 2.5)
1 x (18 – 14)
2 x (18 – 14)
42 – 480
24 – 250
0.7 – 1.1
0.7 – 1.1
5
3
3
3
50
CA08102001E
Rated
Current
March 2009
n [A]
Rated
Current
63
n [A]

Related parts for XTOB004CC1