XTOB004CC1 EATON CUTLER HAMMER, XTOB004CC1 Datasheet - Page 199

Overload Relay

XTOB004CC1

Manufacturer Part Number
XTOB004CC1
Description
Overload Relay
Manufacturer
EATON CUTLER HAMMER
Datasheet

Specifications of XTOB004CC1

Overload Adjustment Current Min
2.4A
Overload Adjustment Current Max
4A
Coil Voltage Dc Max
220V
Contactor Direction
Non Reversing
Coil Voltage Vdc Nom
220V
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
March 2009
Table 34-229. P — Pilot Lights, Pushbuttons, Phase Relays, Potential
Transformers, Power Factor Correction Capacitors, Program Timer,
Percentage Timer, Photocell (Continued)
Table 34-230. Q — IQ Products, DN50
CA08102001E
Modification Catalog
Pilot Lights
(Continued)
Illuminated
Pushbutton
Phase Loss
Relay
Phase
Reversal
Relay
Phase
Unbalance
Relay
Phase
Monitoring
Relay
Power Factor
Correction
Capacitors
Potential
Transformers
Program
Timers
Percentage
Timers
Modification
IQ Products
IQ Data
Metering
Module
DN50
Number
Suffix
P61
P62
P63
P64
P65
P66
P67
P68
P69
P27
P28
P30
P32
P34
P38
P39
P40
P41
P43
P44
P45
P47
P48
Catalog
Number
Suffix
Q1
Q3
Q5
Q12
Q14
Q13
Potential Transformer — Wired L1 – L2
Potential Transformer — Wired L1– L2
and L2 – L3
Potential Transformer — 3 Phases
15-Minute Program Timer
24-Hour Program Timer
7-Day Program Timer with
Day Omission Feature
15-Minute Percentage Timer
60-Minute Percentage Timer
Description
Pilot Light — Green STOP
FORWARD/REVERSE Red Pilot Lights
UP/DOWN Red Pilot Lights
OPEN/CLOSE Red Pilot Lights
HIGH/LOW Red Pilot Lights
FAST/SLOW Red Pilot Lights
Green RUN Light
LED Bulbs
Blue OVERLOAD Light
Illuminated Pushbutton — Order by
Description
Phase Loss Relay
Phase Reversal Relay
Phase Unbalance Relay
Phase Monitoring Relay
/F1 20 kVar
/F2 25 kVar
/F3 30 kVar
/F4 35 kVar
/F5 40 kVar
/F6 45 kVar
/F7 50 kVar
/F8 60 kVar
Description
IQ 500
IQ 1000
IQ 4000
IQ Data Metering Module
IQ 220 with Cable
DeviceNet Input/Output Module
/F10
/F11
/F12
/F13 100 kVar
/F14 125 kVar
/F15 150 kVar
/F16 175 kVar
/F9
70 kVar
75 kVar
80 kVar
90 kVar
/F17 200 kVar
/F18 225 kVar
/F19 250 kVar
/F20 300 kVar
/F21 350 kVar
/F22 400 kVar
For more information visit: www.eaton.com
IEC Contactors & Starters
XT IEC Power Control
Contactors and Starters — Enclosed Control
U.S. $
Adder
Adder
U.S. $
Table 34-231. R — Ramp, Relays, Solid-State Electronic Overload
Relays, Resets, Overload Relay Modifications, Reversing,
DeviceNet Interface
Modification Catalog
Relay
Solid-State
Electronic
Overload
Relay
Resets
DeviceNet
Interface
Features:
Complete Modification Code includes overload range. Example R61/C.
• Self-Powered
• Phase Loss Protection
• Current Adjustment Knob
• ± 1% Repeat Accuracy
• 1NO and 1NC Isolated Contacts
Catalog Number Suffix
B & C
C & D
D
F & G
G
N/A
N/A
Number
Suffix
R2
IEC
Frame
R5
R6
R44
R45
R47
R71
R69
R65
R66
R67
Description
Overvoltage Relay
Full Load Current
Adjustment Range
(A)
192 – 600
Change External Reset to Internal Reset —
Hole Covered with Plug
Internal Reset — No Hole Plug
Manual Reset Only on Overload Relay
Auto Reset Only on Overload Relay
Internal Trip Indicator — No External Reset
N3R Reset Boot Added (Type 1/12 Only)
DeviceNet Interface
Standard Reset for DeviceNet
Lighted Reset for DeviceNet
Trip Indicator for DeviceNet
15 – 75
22 – 110
30 – 150
96 – 300
Discount Symbol . . . . . . . . . . . . . . . . . . . . . . . 1CD1C
0.1 – 0.5
0.4 – 2.0
1.0 – 5.0
1.6 – 8.0
0.1 – 0.5
0.4 – 2.0
1.0 – 5.0
1.6 – 8.0
6.4 – 32
9 – 45
3-Phase Automatic/
Manual Reset
Class 5/10/20/30
R61_
A
B
C
D
A
B
C
D
E
F
G
H
J
C
C
Adder
U.S. $
34-199
34

Related parts for XTOB004CC1