XTOB004CC1 EATON CUTLER HAMMER, XTOB004CC1 Datasheet - Page 227

Overload Relay

XTOB004CC1

Manufacturer Part Number
XTOB004CC1
Description
Overload Relay
Manufacturer
EATON CUTLER HAMMER
Datasheet

Specifications of XTOB004CC1

Overload Adjustment Current Min
2.4A
Overload Adjustment Current Max
4A
Coil Voltage Dc Max
220V
Contactor Direction
Non Reversing
Coil Voltage Vdc Nom
220V
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
March 2009
Index of Enclosure Ratings — IEC
Table 34-267. 1st Characteristic Numeral
NEMA Definitions Pertaining to Non-hazardous Locations —
NEMA Standard 250
Type 1
Enclosures are intended for indoor use, primarily to provide a degree of protection
against contact with the enclosed equipment.
Type 3
Enclosures are intended for outdoor use, primarily to provide a degree of protec-
tion against windblown dust, rain, sleet and external ice formation.
Type 3R
Enclosures are intended for outdoor use, primarily to provide a degree of
protection against falling rain, sleet and external ice formation.
Type 4
Enclosures are intended for indoor or outdoor use, primarily to provide a degree
of protection against windblown dust and rain, splashing water and hose-directed
water.
Type 4X
Enclosures are intended for indoor or outdoor use, primarily to provide a degree
of protection against corrosion, windblown dust and rain, splashing water and
hose-directed water.
Type 6
Enclosures are intended for indoor or outdoor use, primarily to provide a degree
of protection against the entry of water during occasional temporary submersion
at a limited depth.
Type 6P
Enclosures are intended for indoor or outdoor use, primarily to provide a degree
of protection against the entry of water during prolonged submersion at a limited
depth.
Type 12
Enclosures are intended for indoor use, primarily to provide a degree of protection
against dust, falling dirt, and dripping non-corrosive liquids.
Type 13
Enclosures are intended for indoor use, primarily to provide a degree of protection
against dust, spraying of water, oil and non-corrosive coolant.
CA08102001E
Protected against contact and penetration of
solid bodies.
0
1
2
3
4
5
6
Not protected.
Protection against solid objects greater
than 50 mm.
Protection against solid objects greater
than 12 mm.
Protection against solid objects greater
than 2.5 mm.
Protection against solid objects greater
than 1.0 mm.
Dust protected.
Dust-tight.
Table 34-268. 2nd Characteristic Numeral
0
1
2
3
4
5
6
7
8
For more information visit: www.eaton.com
IEC Contactors & Starters
XT IEC Power Control
Reference Data
Not protected.
Protection against dripping water.
Protection against dripping water when
tilted up to 15 degrees.
Protection against rain.
Protection against splashing water.
Protection against water jets.
Protection against heavy seas.
Protection against the effects of
immersion.
Protection against submersion.
NEC Definitions Pertaining to
Hazardous Locations —
Article 500
E51 Limit Switch Type Proximity
Switches are rated for use in the fol-
lowing locations:
Class I Division 2, Groups A, B, C or D —
Indoor Use
Class II Division 2, Groups F or G —
Indoor Use
Class III Division 2 — Indoor Use
For the definition of a Class I
Division 2 location, see National
Electrical Code Article 500-5,
paragraph (b).
For the definitions of Class I Group
A, B, C, D Classifications, see the
National Electrical Code Article
500-3, paragraph (a).
For the definition of a Class II
Division 2 location, see National
Electrical Code Article 500-6,
paragraph (b).
For the definitions of Class II Group
F and G Classifications, see the
National Electrical Code Article
500-3, paragraph (b).
For the definition of a Class III
Division 2 location, see National
Electrical Code Article 500-7,
paragraph (b).
For the definitions of Class III
Classifications, see the National
Electrical Code Article 500-7.
34-227