XTOB004CC1 EATON CUTLER HAMMER, XTOB004CC1 Datasheet - Page 158

Overload Relay

XTOB004CC1

Manufacturer Part Number
XTOB004CC1
Description
Overload Relay
Manufacturer
EATON CUTLER HAMMER
Datasheet

Specifications of XTOB004CC1

Overload Adjustment Current Min
2.4A
Overload Adjustment Current Max
4A
Coil Voltage Dc Max
220V
Contactor Direction
Non Reversing
Coil Voltage Vdc Nom
220V
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
34-158
34
Standards and Certifications
UL 508 Type F Combination Motor
Controller
Note: For Type 2 Coordination of MMCs,
see Tables 34-249 through 34-251 on Pages
34-210 and 34-211.
Protection in Different Controller
Types
A UL 508 Type E Self-protected Manual
Combination Starter/Motor Controller
consists of a single device having inte-
gral short circuit protection, a main set
of contacts, motor overload protec-
tion, and may also include a UL listed
Line Side Adapter (see Table 34-187).
This type of controller is a legitimate
short circuit protective device and dis-
connect means for the downstream
motor. It does require an upstream
feeder short circuit protective device,
but does not require a dedicated
branch circuit protection or a discon-
nect means if used with a Line Side
Adapter. A UL 508 Type E rating means
that the unit clears a fault and does not
experience any welding of the power
poles. A UL 508 Type E self-protected
manual motor controller will remain
fully functional should a short circuit
within its ratings occur. E.g. XTPR.
An
Combination Motor Controller consists
of a UL Listed Type E Self-protected
Manual Combination Starter/Motor
Controller, a UL Listed Contactor, and
a UL Listed Line Side Adapter (see
Table 34-187). While the UL 508 Type E
self-protected manual motor protector
of this combination motor controller
device is a legitimate short circuit
protective device and disconnect
means for the downstream motor,
the contactor is not “self-protected.”
E.g. XTFC, XTFR.
In addition, as a complete assembly or
modular components, the device
should have Type 2 Coordination certi-
fication. Type 2 Coordination means
the Starter or the Controller must
exhibit little or no damage following a
major short circuit fault and should be
able to be returned to proper service
without replacing any parts.
IEC Type 2 Approved per
IEC 60947-4-1
UL Listed File No. E245398
CE Mark
IEC Contactors & Starters
XT IEC Power Control
Combination Motor Controllers
UL 508 Type F Self-protected
Table 34-187. MMC and CMC Applications
Reference: Technical Paper AP03402001E.
Note: Line Side Adapters are not required for non-U.S. applications. Most countries outside
of the U.S. classify the MMP as a thermal magnetic circuit breaker.
For more information visit: www.eaton.com
SCPD = Short Circuit Protective Device (Circuit Breaker, Fuses).
MMC = Manual Motor Controller
XTSC / XTSR
Using the in-panel Main
SCPD
without a factory
assembled LSA.
Not required
Manual Motor Controller
Line Side Adapter (LSA)
Group Installation
XT IEC Manual & Combination Motor Controllers
and an MMC
Only Upstream Feeder SCPD
assembled LSA; no dedicated in-panel Main SCPD
for CMC.
UL 508 Type F Combination Motor Controller
XTFC / XTFR
Combination Motor Controller
Required — Factory
Assembled
Line Side Adapter (LSA)
required with factory
CA08102001E
March 2009