WM9713LGEFL/RV Wolfson Microelectronics, WM9713LGEFL/RV Datasheet - Page 56

Audio CODECs Stereo AC'97 CODEC T/P Interface

WM9713LGEFL/RV

Manufacturer Part Number
WM9713LGEFL/RV
Description
Audio CODECs Stereo AC'97 CODEC T/P Interface
Manufacturer
Wolfson Microelectronics
Datasheet

Specifications of WM9713LGEFL/RV

Number Of Adc Inputs
1
Number Of Dac Outputs
1
Conversion Rate
8 KSPs
Interface Type
AC97
Resolution
12 bit
Maximum Operating Temperature
+ 85 C
Mounting Style
SMD/SMT
Package / Case
QFN-48
Minimum Operating Temperature
- 25 C
Number Of Channels
1 ADC, 1 DAC
Lead Free Status / RoHS Status
Lead free / RoHS Compliant

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
WM9713LGEFL/RV
Manufacturer:
WOLFSON
Quantity:
20 000
WM9713L
MONO OUTPUT
w
Table 33 HPL / HPR PGA Control
The MONO output (pin 31) is designed to drive a 16Ω headphone load and can also be used as a
line output. The available input sources are MONOMIX, INV1 and Vmid (see Table 34)
Table 34 MONO PGA Input Source
The signal volume on MONO can be independently adjusted under software control by writing to
register 08h.
When not in use MONO can be powered down using the Powerdown register bit MONO (register
3Eh, bit 13). To minimise pops and clicks when the PGA is powered down / up it is recommended
that the Vmid input is selected during the power down / up cycle. This ensures the same DC level is
maintained on the output pin throughout.
04h
Headphone
Volume
1Ch
Output PGA
Mux Select
REGISTER
REGISTER
ADDRESS
ADDRESS
15
14
13:8
7
6
5:0
15:14
BIT
BIT
MUL
ZCL
HPLVOL
MUR
ZCR
HPRVOL
MONO
LABEL
LABEL
1 (Mute)
0
000000
(0dB)
1 (Mute)
0
000000
(0dB)
00 (Vmid)
DEFAULT
DEFAULT
HPL Mute Control
1 = Mute
0 = No mute
HPL Zero Cross Control
1 = Zero cross enabled (change volume
only on zero crossings, or after time-out)
0 = Zero cross disabled (change volume
immediately)
HPL Volume Control
000000 = 0dB (maximum)
… (1.5dB steps)
011111 = -46.5dB
1xxxxx = -46.5dB
HPR Mute Control
1 = Mute
0 = No mute
HPR Zero Cross Control
1 = Zero cross enabled (change volume
only on zero crossings, or after time-out)
0 = Zero cross disabled (change volume
immediately)
HPR Volume Control
000000 = 0dB (maximum)
… (1.5dB steps)
011111 = -46.5dB
1xxxxx = -46.5dB
MONO Source Control
00 = VMID
01 = No input (tri-stated if MONO is
disabled in 3Eh)
10 = MONOMIX
11 = INV1
DESCRIPTION
DESCRIPTION
PP Rev 3.2 September 2008
Pre-Production
56