EP1SGX40GF1020I6 Altera, EP1SGX40GF1020I6 Datasheet - Page 125

no-image

EP1SGX40GF1020I6

Manufacturer Part Number
EP1SGX40GF1020I6
Description
IC STRATIX GX FPGA 40K 1020-FBGA
Manufacturer
Altera
Series
Stratix® GXr
Datasheet

Specifications of EP1SGX40GF1020I6

Number Of Logic Elements/cells
41250
Number Of Labs/clbs
4125
Total Ram Bits
3423744
Number Of I /o
624
Voltage - Supply
1.425 V ~ 1.575 V
Mounting Type
Surface Mount
Operating Temperature
-40°C ~ 100°C
Package / Case
1020-FBGA
Family Name
Stratix GX
Number Of Logic Blocks/elements
41250
# I/os (max)
624
Frequency (max)
5GHz
Process Technology
SRAM
Operating Supply Voltage (typ)
1.5V
Logic Cells
41250
Ram Bits
3423744
Operating Supply Voltage (min)
1.425V
Operating Supply Voltage (max)
1.575V
Operating Temp Range
-40C to 100C
Operating Temperature Classification
Industrial
Mounting
Surface Mount
Pin Count
1020
Package Type
FC-FBGA
Lead Free Status / RoHS Status
Contains lead / RoHS non-compliant
Number Of Gates
-
Lead Free Status / Rohs Status
Not Compliant

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
EP1SGX40GF1020I6
Manufacturer:
ALTERA
Quantity:
1 238
Part Number:
EP1SGX40GF1020I6
Manufacturer:
ALTERA
Quantity:
3 000
Part Number:
EP1SGX40GF1020I6
Manufacturer:
Altera
Quantity:
10 000
Part Number:
EP1SGX40GF1020I6
Manufacturer:
ALTERA
0
Part Number:
EP1SGX40GF1020I6N
Manufacturer:
Altera
Quantity:
10 000
Part Number:
EP1SGX40GF1020I6N
Manufacturer:
XILINX
0
Part Number:
EP1SGX40GF1020I6N
Manufacturer:
ALTERA
0
Altera Corporation
February 2005
Output Selection Multiplexer
The outputs from the various elements of the adder/output block are
routed through an output selection multiplexer. Based on the DSP block
operational mode and user settings, the multiplexer selects whether the
output from the multiplier, the adder/subtractor/accumulator, or
summation block feeds to the output.
Output Registers
Optional output registers for the DSP block outputs are controlled by four
sets of control signals: clock[3..0], aclr[3..0], and ena[3..0].
Output registers can be used in any mode.
Modes of Operation
The adder, subtractor, and accumulate functions of a DSP block have four
modes of operation:
1
Simple Multiplier Mode
In simple multiplier mode, the DSP block drives the multiplier sub-block
result directly to the output with or without an output register. Up to four
18
directly out of one DSP block. See
×
Simple multiplier
Multiply-accumulator
Two-multipliers adder
Four-multipliers adder
18-bit multipliers or eight 9
Each DSP block can only support one mode. Mixed modes in the
same DSP block is not supported.
×
9-bit multipliers can drive their results
Figure
Stratix GX Device Handbook, Volume 1
4–34.
Stratix GX Architecture
4–59