PEB2256H-V12 Infineon Technologies, PEB2256H-V12 Datasheet - Page 274

no-image

PEB2256H-V12

Manufacturer Part Number
PEB2256H-V12
Description
IC INTERFACE LINE 3.3V 80-MQFP
Manufacturer
Infineon Technologies
Datasheet

Specifications of PEB2256H-V12

Applications
*
Interface
*
Voltage - Supply
*
Package / Case
80-SQFP
Mounting Type
Surface Mount
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Other names
PEB2256H-V12
PEB2256H-V12IN

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
PEB2256H-V12
Manufacturer:
Infineon Technologies
Quantity:
10 000
RFT13, RFT03
Common Configuration Register 5 (Read/Write)
Value after reset: 00
CCR5
SUET
CSF
AFX
Data Sheet
7
RFIFO3 Threshold Level - HDLC Channel 3
The size of the accessible part of RFIFO3 can be determined by
programming these bits. The number of valid bytes after an RPF
interrupt is given in the following table:
RFT13
0
0
1
1
The value of RFT13/03 can be changed dynamically if reception is not
running or after the current data block has been read, but before the
command CMDR4.RMC3 is issued (interrupt controlled data
transfer).
Note: These bits are only valid, if SS7 mode of HDLC channel 1 is
Signaling Unit Error Threshold
Defines the number of signaling units received in error that will cause
an error rate high indication (ISR1.SUEX).
0 =
1 =
Compare Status Field
If the status fields of consecutive LSSUs are equal, only the first is
stored and every following is ignored.
0 =
1 =
Automatic FISU Transmission
After the contents of the transmit FIFO (XFIFO) has been transmitted
completely, FISUs are transmitted automatically. These FISUs
contain the FSN and BSO of the last transmitted signaling unit.
H
selected.
Threshold 64 errored signaling units
Threshold 32 errored signaling units
Compare disabled.
Compare enabled.
SUET
RFT03
0
1
0
1
CSF
Size of Accessible Part of RFIFO3
32 bytes (default value)
16 bytes
4 bytes
2 bytes
274
AFX
FALC56 V1.2
E1 Registers
0
PEB 2256
2002-08-27
(x8D)

Related parts for PEB2256H-V12