PSB 2132 H V2.2 Infineon Technologies, PSB 2132 H V2.2 Datasheet - Page 21

IC CODEC FILTER 2CHAN MQFP-64

PSB 2132 H V2.2

Manufacturer Part Number
PSB 2132 H V2.2
Description
IC CODEC FILTER 2CHAN MQFP-64
Manufacturer
Infineon Technologies
Series
SICOFI®r
Datasheet

Specifications of PSB 2132 H V2.2

Package / Case
64-QFP
Function
CODEC Filter
Interface
IOM-2 PCM, SPI
Number Of Circuits
2
Voltage - Supply
5V
Current - Supply
18mA
Power (watts)
90mW
Mounting Type
Surface Mount
Includes
Level Metering Function, Tone Generation
Number Of Adc Inputs
2
Number Of Dac Outputs
2
Interface Type
Serial
Operating Supply Voltage
5 V
Maximum Operating Temperature
+ 70 C
Mounting Style
SMD/SMT
Minimum Operating Temperature
0 C
Number Of Channels
2
Snr
35.4 dB
Supply Current
40 mA
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Operating Temperature
-
Lead Free Status / RoHS Status
Lead free / RoHS Compliant, Lead free / RoHS Compliant
Other names
PSB2132HV2.2XT
SP000007696
4
Each channel of the SICOFI
“Operating”. These states can be switched by programming Bit 0 (PU) in the
channel-specific configuration register CR1. “Standby” is a power-saving state. Keeping
any unused channels in this state reduces the overall system power dissipation. The
third state, “Reset”, is transient and is reached after applying power to the device (Power
On), after asserting a logic low signal to the RESET#-pin (HW-Reset), or after issuing an
XOP command with Bit 7 (RST) set to "1" (SW-Reset). Both channels would be affected
in any case.
4.1
Figure 5
4.1.1
All input pins must be at GND level before applying VDD to the SICOFI
the device may not enter the Reset State. In this case, the SICOFI
HW- or SW-Reset, or can be initialized by setting all registers to zero.
Hardware Reference Manual
Operational Description
Operating States
Power On
Power Up Ch.1
SICOFI
Power-On
HW-Reset
SW-Reset
®
2-TE State Diagram
Operating
Standby
Ch.1
Ch.1
®
Power Down Ch.1
2-TE can be in one of two stable states: “Standby” and
(both channels)
Reset
12
Power Up Ch.2
Operating
Standby
Ch.2
Ch.2
Operational Description
Power Down Ch.2
®
2-TE can be reset by
®
2-TE. Otherwise,
PSB 2132
2001-02-20
2132_206