M29W640FT70ZA6E NUMONYX, M29W640FT70ZA6E Datasheet - Page 16

IC FLASH 64MBIT 70NS 48TFBGA

M29W640FT70ZA6E

Manufacturer Part Number
M29W640FT70ZA6E
Description
IC FLASH 64MBIT 70NS 48TFBGA
Manufacturer
NUMONYX
Series
Axcell™r
Datasheet

Specifications of M29W640FT70ZA6E

Format - Memory
FLASH
Memory Type
FLASH - Nor
Memory Size
64M (8Mx8, 4Mx16)
Speed
70ns
Interface
Parallel
Voltage - Supply
2.7 V ~ 3.6 V
Operating Temperature
-40°C ~ 85°C
Package / Case
48-TFBGA
Package
48TFBGA
Cell Type
NOR
Density
64 Mb
Architecture
Sectored
Block Organization
Asymmetrical
Location Of Boot Block
Top
Typical Operating Supply Voltage
3|3.3 V
Sector Size
8KByte x 8|64KByte x 127
Timing Type
Asynchronous
Interface Type
Parallel
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Other names
497-5034
497-5034

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
M29W640FT70ZA6E
Manufacturer:
Micron Technology Inc
Quantity:
10 000
Part Number:
M29W640FT70ZA6E
Manufacturer:
ST
0
3.5
3.6
3.6.1
3.6.2
16/71
Automatic Standby
If CMOS levels (V
more the memory enters Automatic Standby where the internal Supply Current is reduced to
the Standby Supply Current, I
Read operation is in progress.
Special Bus operations
Additional bus operations can be performed to read the Electronic Signature and also to
apply and remove Block Protection. These bus operations are intended for use by
programming equipment and are not usually used in applications. They require V
applied to some pins.
Electronic Signature
The memory has two codes, the manufacturer code and the device code, that can be read
to identify the memory. These codes can be read by applying the signals listed in
Bus operations, BYTE = V
Block Protect and Chip Unprotect
Groups of blocks can be protected against accidental Program or Erase. The Protection
Groups are shown in
can be unprotected to allow the data inside the blocks to be changed.
The V
V
protected regardless of the Block Protection Status or the Reset/Block Temporary
Unprotect pin status.
Block Protect and Chip Unprotect operations are described in
PP
/Write Protect is at V
PP
/Write Protect pin can be used to protect the two outermost boot blocks. When
CC
± 0.2V) are used to drive the bus and the bus is inactive for 300ns or
Appendix A: Block addresses Table 21
IL
IL
the two outermost boot blocks are protected and remain
and
CC2
Table 5: Bus operations, BYTE = V
. The Data Inputs/Outputs will still output data if a Bus
and
Appendix D: Block
Table
IH
.
22. The whole chip
ID
protection.
Table 4:
to be

Related parts for M29W640FT70ZA6E