M29W640FT70ZA6E NUMONYX, M29W640FT70ZA6E Datasheet - Page 18

IC FLASH 64MBIT 70NS 48TFBGA

M29W640FT70ZA6E

Manufacturer Part Number
M29W640FT70ZA6E
Description
IC FLASH 64MBIT 70NS 48TFBGA
Manufacturer
NUMONYX
Series
Axcell™r
Datasheet

Specifications of M29W640FT70ZA6E

Format - Memory
FLASH
Memory Type
FLASH - Nor
Memory Size
64M (8Mx8, 4Mx16)
Speed
70ns
Interface
Parallel
Voltage - Supply
2.7 V ~ 3.6 V
Operating Temperature
-40°C ~ 85°C
Package / Case
48-TFBGA
Package
48TFBGA
Cell Type
NOR
Density
64 Mb
Architecture
Sectored
Block Organization
Asymmetrical
Location Of Boot Block
Top
Typical Operating Supply Voltage
3|3.3 V
Sector Size
8KByte x 8|64KByte x 127
Timing Type
Asynchronous
Interface Type
Parallel
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Other names
497-5034
497-5034

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
M29W640FT70ZA6E
Manufacturer:
Micron Technology Inc
Quantity:
10 000
Part Number:
M29W640FT70ZA6E
Manufacturer:
ST
0
4
4.1
4.1.1
4.1.2
18/71
Command interface
All Bus Write operations to the memory are interpreted by the Command Interface.
Commands consist of one or more sequential Bus Write operations. Failure to observe a
valid sequence of Bus Write operations will result in the memory returning to Read mode.
The long command sequences are imposed to maximize data security.
The address used for the commands changes depending on whether the memory is in 16-
bit or 8-bit mode. See either
used, for a summary of the commands.
Standard commands
Read/Reset command
The Read/Reset command returns the memory to its Read mode. It also resets the errors in
the Status Register. Either one or three Bus Write operations can be used to issue the
Read/Reset command.
The Read/Reset command can be issued, between Bus Write cycles before the start of a
program or erase operation, to return the device to read mode. If the Read/Reset command
is issued during the timeout of a Block Erase operation then the memory will take up to 10μs
to abort. During the abort period no valid data can be read from the memory. The
Read/Reset command will not abort an Erase operation when issued while in Erase
Suspend.
Auto Select command
The Auto Select command is used to read the Manufacturer Code, the Device Code, the
Block Protection Status and the Extended Memory Block Verify Code. Three consecutive
Bus Write operations are required to issue the Auto Select command. Once the Auto Select
command is issued the memory remains in Auto Select mode until a Read/Reset command
is issued. Read CFI Query and Read/Reset commands are accepted in Auto Select mode,
all other commands are ignored.
In Auto Select mode, the Manufacturer Code and the Device Code can be read by using a
Bus Read operation with addresses and control signals set as shown in
operations, BYTE = V
‘Don’t Care’.
The Block Protection Status of each block can be read using a Bus Read operation with
addresses and control signals set as shown in
Table 5: Bus operations, BYTE = V
block is protected then 01h is output on Data Inputs/Outputs DQ0-DQ7, otherwise 00h is
output (in 8-bit mode).
The protection status of the Extended Memory block, or Extended Memory Block Verify
code, can be read using a Bus Read operation with addresses and control signals set as
shown in
except for A9 that is ‘Don’t Care’. If the Extended Block is "Factory Locked" then 80h is
output on Data Input/Outputs DQ0-DQ7, otherwise 00h is output (8-bit mode).
Table 4: Bus operations, BYTE = V
IL
and
Table
Table 5: Bus operations, BYTE = V
6, or
IH
, except for A9 that is ‘Don’t Care’. If the addressed
Table
IL
7, depending on the configuration that is being
and
Table 4: Bus operations, BYTE = V
Table 5: Bus operations, BYTE = V
IH
, except for A9 that is
Table 4: Bus
IL
and
IH
,

Related parts for M29W640FT70ZA6E