HD64F3048F16 Renesas Electronics America, HD64F3048F16 Datasheet - Page 93

IC H8 MCU FLASH 128K 100QFP

HD64F3048F16

Manufacturer Part Number
HD64F3048F16
Description
IC H8 MCU FLASH 128K 100QFP
Manufacturer
Renesas Electronics America
Series
H8® H8/300Hr
Datasheets

Specifications of HD64F3048F16

Core Processor
H8/300H
Core Size
16-Bit
Speed
8MHz
Connectivity
SCI, SmartCard
Peripherals
DMA, PWM, WDT
Number Of I /o
70
Program Memory Size
128KB (128K x 8)
Program Memory Type
FLASH
Ram Size
4K x 8
Voltage - Supply (vcc/vdd)
4.5 V ~ 5.5 V
Data Converters
A/D 8x10b; D/A 2x8b
Oscillator Type
Internal
Operating Temperature
-20°C ~ 75°C
Package / Case
100-QFP
Package
100PQFP
Family Name
H8
Maximum Speed
16 MHz
Operating Supply Voltage
5 V
Data Bus Width
16|32 Bit
Number Of Programmable I/os
70
Interface Type
SCI
On-chip Adc
8-chx10-bit
On-chip Dac
2-chx8-bit
Number Of Timers
5
Lead Free Status / RoHS Status
Contains lead / RoHS non-compliant
Eeprom Size
-

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
HD64F3048F16
Manufacturer:
RENESAS
Quantity:
1
Part Number:
HD64F3048F16
Manufacturer:
Renesas Electronics America
Quantity:
10 000
Part Number:
HD64F3048F16
Manufacturer:
HIT
Quantity:
1 000
Part Number:
HD64F3048F16
Manufacturer:
RENESAS
Quantity:
20 000
Part Number:
HD64F3048F16V
Manufacturer:
SIEMENS
Quantity:
200
Part Number:
HD64F3048F16V
Manufacturer:
RENESAS
Quantity:
5 530
Part Number:
HD64F3048F16V
Manufacturer:
RENESAS
Quantity:
3 477
Part Number:
HD64F3048F16V
Manufacturer:
RENESAS/瑞萨
Quantity:
20 000
is cleared to 0, the CPU sets both the I bit and the UI bit in the condition code register to 1. Then
the CPU fetches a start address from the exception vector table and execution branches to that
address.
Figure 2.14 shows the stack after the exception-handling sequence.
2.8.5
In this state the bus is released to a bus master other than the CPU, in response to a bus request.
The bus masters other than the CPU are the DMA controller, the refresh controller, and an external
bus master. While the bus is released, the CPU halts except for internal operations. Interrupt
requests are not accepted. For details see section 6.3.7, Bus Arbiter Operation.
SP (ER7)
Legend:
CCR:
SP:
Notes: 1.
SP
SP
SP
SP
Condition code register
Stack pointer
2.
Bus-Released State
4
3
2
1
PC is the address of the first instruction executed after the return from the
exception-handling routine.
Registers must be saved and restored by word access or longword access,
starting at an even address.
Figure 2.14 Stack Structure after Exception Handling
Before exception
handling starts
Stack area
Pushed on stack
SP (ER7)
SP + 1
SP + 2
SP + 3
SP + 4
Rev. 3.00 Sep 27, 2006 page 65 of 872
After exception
handling ends
CCR
PC
REJ09B0325-0300
Section 2 CPU
Even
address