M37542F8FP Renesas Electronics America, M37542F8FP Datasheet - Page 110

IC 740 MCU FLASH 32K 36SSOP

M37542F8FP

Manufacturer Part Number
M37542F8FP
Description
IC 740 MCU FLASH 32K 36SSOP
Manufacturer
Renesas Electronics America
Series
740/38000r
Datasheet

Specifications of M37542F8FP

Core Processor
740
Core Size
8-Bit
Speed
8MHz
Connectivity
SIO, UART/USART
Peripherals
POR, WDT
Number Of I /o
29
Program Memory Size
32KB (32K x 8)
Program Memory Type
FLASH
Ram Size
1K x 8
Voltage - Supply (vcc/vdd)
2.2 V ~ 5.5 V
Data Converters
A/D 8x10b
Oscillator Type
Internal
Operating Temperature
-20°C ~ 85°C
Package / Case
36-SSOP
Lead Free Status / RoHS Status
Contains lead / RoHS non-compliant
Eeprom Size
-

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
M37542F8FP
Manufacturer:
MIT
Quantity:
20 000
Part Number:
M37542F8FP#U0
Manufacturer:
TI
Quantity:
109
APPENDIX
NOTES ON PROGRAMMING
1. Processor Status Register
(1) Initializing of processor status register
Flags which affect program execution must be initialized after a re-
set.
In particular, it is essential to initialize the T and D flags because
they have an important effect on calculations.
<Reason>
After a reset, the contents of the processor status register (PS) are
undefined except for the I flag which is “1”.
Fig. 1 Initialization of processor status register
(2) How to reference the processor status register
To reference the contents of the processor status register (PS), ex-
ecute the PHP instruction once then read the contents of (S+1). If
necessary, execute the PLP instruction to return the PS to its origi-
nal status.
7542 Group
Fig. 2 Stack memory contents after PHP instruction execution
Rev.3.03
REJ03B0006-0303
(S)+1
Jul 11, 2008
(S)
Initializing of flags
Main program
Reset
Stored PS
Page 108 of 117
2. Decimal calculations
(1) Execution of decimal calculations
The ADC and SBC are the only instructions which will yield proper
decimal notation, set the decimal mode flag (D) to “1” with the
SED instruction. After executing the ADC or SBC instruction, ex-
ecute another instruction before executing the SEC, CLC, or CLD
instruction.
(2) Notes on status flag in decimal mode
When decimal mode is selected, the values of three of the flags in
the status register (the N, V, and Z flags) are invalid after a ADC or
SBC instruction is executed.
The carry flag (C) is set to “1” if a carry is generated as a result of
the calculation, or is cleared to “0” if a borrow is generated. To de-
termine whether a calculation has generated a carry, the C flag
must be initialized to “0” before each calculation. To check for a
borrow, the C flag must be initialized to “1” before each calcula-
tion.
Fig. 3 Status flag at decimal calculations
3. JMP instruction
When using the JMP instruction in indirect addressing mode, do
not specify the last address on a page as an indirect address.
4.Multiplication and Division Instructions
(1) The index X mode (T) and the decimal mode (D) flags do not
(2) The execution of these instructions does not change the con-
affect the MUL and DIV instruction.
tents of the processor status register.
SEC, CLC, or CLD instruction
ADC or SBC instruction
Set D flag to “1”
NOP instruction

Related parts for M37542F8FP