SLRC40001T/OFE,112 NXP Semiconductors, SLRC40001T/OFE,112 Datasheet - Page 103

IC I.CODE SLRC400 READER 32-SOIC

SLRC40001T/OFE,112

Manufacturer Part Number
SLRC40001T/OFE,112
Description
IC I.CODE SLRC400 READER 32-SOIC
Manufacturer
NXP Semiconductors
Series
I-Coder

Specifications of SLRC40001T/OFE,112

Rf Type
Read Only
Frequency
13.56MHz
Features
ISO15693, ISO18000-3
Package / Case
32-SOIC (0.300", 7.50mm Width)
Product
RFID Readers
Operating Temperature Range
- 25 C to + 85 C
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Lead Free Status / RoHS Status
Lead free / RoHS Compliant, Lead free / RoHS Compliant
Other names
568-1124-5
935269551112
SLRC400
SLRC41TOFED
Philips Semiconductors
I•CODE Reader IC
16.4.2.4 Communication Errors
The following table shows which event causes the setting of error flags:
Cause
Received data did not start with a SOF pattern.
The CRC block is not equal the expected value.
The received data is shorter than the CRC block.
A collision is detected.
16.4.3 TRANSCEIVE COMMAND 1E
The Transceive-Command first executes the Transmit-Command (see 16.4.1) and then automatically starts
the Receive-Command (see 16.4.2). All data that shall be transmitted is forwarded via the FIFO buffer and all
data received is returned via the FIFO buffer. The Transceive-Command can be started only by the
µ-Processor.
Note: To adjust the timing relation between transmitting and receiving, the RxWait Register is used to define
the time delay from the last bit transmitted until the receiver is activated. Furthermore, the BitPhase Register
determines the phase-shift between the transmitter and the receiver clock.
16.4.4 STATES OF THE LABEL COMMUNICATION
The actual state of the transmitter and receiver state machine can be fetched from ModemState in the
PrimaryStatus Register.
The assignment of ModemState to the internal action is shown in the following table:
Command
Transceive
ModemState
000
001
010
011
100
101
110
111
Code
1E
hex
Transmits data from FIFO buffer to the label
and then activates automatically the receiver
Name of State
AwaitingRx
PrepareRx
Receiving
GoToRx1
GoToRx2
TxSOF
TxData
TxEOF
Idle
Table 16-3: Communication Error Table
Table 16-4: Meaning of ModemState
HEX
Action
Neither the transmitter nor the receiver is in operation,
since none of them is started or the transmitter has not got input data
Transmitting the ‘Start Of Frame’ Pattern
Transmitting data from the FIFO buffer (or redundancy check bits)
Transmitting the ‘End Of Frame’ Pattern
Receiving data
Intermediate state passed, when receiver starts
Intermediate state passed, when receiver finishes
Waiting until the time period selected in the RxWait Register has expired
Receiver activated; Awaiting an input signal at pin Rx
103
Product Specification Rev. 3.1 August 2004
Data Stream
Description
Arguments and Data
Bit, that is set
Data Stream
Returned Data
SL RC400
FramingErr
CRCErr
CRCErr
CollErr

Related parts for SLRC40001T/OFE,112