CS1D-IC102D Omron, CS1D-IC102D Datasheet - Page 338

no-image

CS1D-IC102D

Manufacturer Part Number
CS1D-IC102D
Description
CS1D Dual IO Control Unit
Manufacturer
Omron
Datasheet

Specifications of CS1D-IC102D

Lead Free Status / Rohs Status
Lead free / RoHS Compliant
Auxiliary Area
Instruction Information
RS-232C Port Communica-
tions Error Flag
RS-232C Port Restart Bit
RS-232C Port Settings
Change Bit
RS-232C Port Error Flags
RS-232C Port Send Ready
Flag
(No-protocol mode)
RS-232C Port Reception
Completed Flag
(No-protocol mode)
RS-232C Port Reception
Overflow Flag
(No-protocol mode)
RS-232C Port PT Communi-
cations Flags
RS-232C Port PT Priority
Registered Flags
RS-232C Port Reception
Counter
(No-protocol mode)
Communications Units 0 to
15, Ports 1 to 4 Settings
Change Bits
Communications Board Ports
1 to 4 Settings Change Bits
Step Flag
Current EM Bank
Macro Area Input Words
Macro Area Output Words
Differentiated Flag Number
Maximum Value
RS-232C Port Communications Information
Serial Device Communications Information
Name
Name
Name
A39204
A52600
A61902
A52800 to
A52807
A39205
A39206
A39207
A39300 to
A39307
A39308 to
A39315
A39300 to
A39315
A62001 to
A63504
A63601 to
A63604
A20012
A301
A600 to
A603
A604 to
A607
A339 to
A340
Address
Address
Address
ON when a communications error has occurred at the RS-
232C port.
Turn this bit ON to restart the RS-232C port.
ON while the RS-232C port’s communications settings are
being changed.
These flags indicate what kind of error has occurred at the
RS-232C port.
ON when the RS-232C port is able to send data in no-proto-
col mode.
ON when the RS-232C port has completed the reception in
no-protocol mode.
ON when a data overflow occurred during reception through
the RS-232C port in no-protocol mode.
The corresponding bit will be ON when the RS-232C port is
communicating with a PT in NT link mode. Bits 0 to 7 corre-
spond to units 0 to 7.
The corresponding bit will be ON for the PT that has priority
when the RS-232C port is communicating in NT link mode.
Bits 0 to 7 correspond to units 0 to 7.
Indicates (in binary) the number of bytes of data received
when the RS-232C port is in no-protocol mode.
The corresponding flag will be ON when the settings for that
port are being changed.
(Bits 1 to 4 in A620 to A635 correspond to ports 1 to 4 in
Communications Units 0 to 15.)
The corresponding flag will be ON when the settings for that
port are being changed.
(Bits 1 to 4 correspond to ports 1 to 4.)
ON for one cycle when step execution is started with
STEP(008).
This word contains the current EM bank number in 4-digit
hexadecimal.
When MCRO(099) is executed, it copies the input data from
the specified source words (input parameter words) to A600
through A603.
After the subroutine specified in MCRO(099) has been exe-
cuted, the results of the subroutine are transferred from
A604 through A607 to the specified destination words (out-
put parameter words).
This word contains the value of the largest Differentiated
Flag number used in the differentiated instructions.
Description
Description
Description
Section 8-11
Read-only
Read/write
Read/write
Read/write
Read-only
Read-only
Read-only
Read-only
Read-only
Read-only
Read/write
Read/write
Read-only
Read-only
Read/write
Read/write
Read-only
Access
Access
Access
303