CS1D-IC102D Omron, CS1D-IC102D Datasheet - Page 55

no-image

CS1D-IC102D

Manufacturer Part Number
CS1D-IC102D
Description
CS1D Dual IO Control Unit
Manufacturer
Omron
Datasheet

Specifications of CS1D-IC102D

Lead Free Status / Rohs Status
Lead free / RoHS Compliant
Specifications
20
Duplex CS1D
Power Sup-
ply Units
Duplex Com-
munications
Units
Duplex Con-
necting
Cables
Online Unit
replacement
using a Pro-
gramming
Devices
Unit Removal
without a Pro-
gramming
Device
Removal/
Addition of
Units without
a Program-
ming Device
Online Addi-
tion of Duplex
Unit
Online Addi-
tion of Units
and Back-
planes
Securing
Expansion
Rack Cables
Item
Operation with two
CS1D Power Supply
Units mounted
Operation when one
CS1D Power Supply
Unit breaks down
When two Optical-ring Controller Link Units for duplex communications (H-PCF
cable: CS1W-CLK12-V1; GI cable: CS1W-CLK52-V1) are mounted using the
same node address and unit number, and a special cable is used to connect
them, one of the Units will continue communications even if the other one breaks
down (active-standby Units)
Duplex Ethernet Units
Two CS1D-ETN21D Ethernet Units are mounted. One is connected to the sec-
ondary communications line and the other to the primary communications line,
thereby increasing reliability of the network (primary/secondary communications
lines).
Two Connecting Cables are installed between the CPU Rack and Expansion
Racks. If one Connecting Cable is removed or damaged, operation continues
using the other cable.
Using the Programming Console, it is possible to mount or remove CS-series
Basic I/O Units, CS-series Special I/O Units, and CS-series CPU Bus Units while
the power is ON and the CPU Unit is operating in any mode (PROGRAM, MON-
ITOR, or RUN).
When Unit removal without a Programming Device is enabled in the PLC Setup,
a Unit can be removed without using the CX-Programmer or a Programming
Console.
Note Unit removal without Programming Device is possible only in a CS1D
If the Removal/Addition of Units without a Programming Device function is
enabled in advance, Units can be removed and mounted without CX-Program-
mer or Programming Console operations.
Note This function is possible only in a Duplex CPU, Dual I/O Expansion Sys-
If there is a Duplex Unit error, the Duplex Unit can be replaced during operation.
The Duplex Unit in which the error occurred can be replaced after turning OFF
power to the Unit by setting the DPL USE/NO USE Switch to NO USE.
Note This function is possible only in a Duplex CPU, Dual I/O Expansion Sys-
A new Basic I/O Unit, Special I/O Unit, or Expansion Backplane can be added
during operation. to an existing Rack. An operating Rack can be expanded with-
out stopping the Rack.
Note This function is possible only in a Duplex CPU, Dual I/O Expansion Sys-
Secure cables help prevent Expansion Rack Cables from being disconnected
accidentally.
Duplex System (Unit Ver. 1.2 or later). After the replacement Unit is
mounted, the Online Replacement Completed Bit must be turned ON.
tem.
tem. The PLC operates in simplex mode while the Duplex Unit is being
replaced.
tem or Duplex CPU, Single I/O Expansion System with CPU Units that
have unit version 1.2 or later. Backplanes can be replaced only in a
Duplex CPU, Dual I/O Expansion System.
Power is supplied to the Backplane simultaneously by two
CS1D Power Supply Units. (The load for each CS1D
Power Supply Unit is approximately one half.)
If one CS1D Power Supply Unit breaks down (i.e., if the
power supply voltage drops), operation is continued using
only the other one.
Specifications
3-2 Duplex Power Sup-
ply Units
Optical Ring Controller
Link Units Operation
Manual (W370)
3-3 Duplex Communi-
cations Units
CS-series CS1D Ether-
net Unit Operation
Manual (W430)
3-4 Duplex Connecting
Cables
11-6 Replacement of
Expansion Units
11-4 Online Replace-
ment of I/O Units, Spe-
cial I/O Units, and CPU
Bus Units
6-1-3 Tab Pages for
Duplex Settings in the
PLC Setup
11-4-5 Online Replace-
ment without a Pro-
gramming Device
6-1-3 Tab Pages for
Duplex Settings in the
PLC Setup
11-4-5 Online Replace-
ment without a Pro-
gramming Device
11-7 Replacing the
Duplex Unit
7-7 Online Addition of
Units and Backplanes
5-2-6 I/O Connecting
Cables
Reference
Section 2-1

Related parts for CS1D-IC102D