M29W256GH7AN6E NUMONYX, M29W256GH7AN6E Datasheet - Page 47

no-image

M29W256GH7AN6E

Manufacturer Part Number
M29W256GH7AN6E
Description
Flash Mem Parallel 3V/3.3V 256M-Bit 32M x 8/16M x 16 70ns 56-Pin TSOP Tray
Manufacturer
NUMONYX
Datasheet

Specifications of M29W256GH7AN6E

Package
56TSOP
Cell Type
NOR
Density
256 Mb
Architecture
Sectored
Block Organization
Symmetrical
Location Of Boot Block
Bottom|Top
Typical Operating Supply Voltage
3|3.3 V
Sector Size
128KByte x 256
Timing Type
Asynchronous
Operating Temperature
-40 to 85 °C
Interface Type
Parallel

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
M29W256GH7AN6E
Manufacturer:
MICRON
Quantity:
1 400
Part Number:
M29W256GH7AN6E
Manufacturer:
ST
0
Part Number:
M29W256GH7AN6E
Manufacturer:
MICRON/镁光
Quantity:
20 000
6.4.5
6.4.6
NVPB lock bit command set
Enter NVPB Lock Bit Command Set command
Three bus write cycles are required to issue the Enter NVPB Lock Bit Command Set
command. Once the command has been issued, the only commands allowing to set the
NVPB lock bit and the Exit Protection Command Set can be issued to the device. Any other
command is ignored. See
NVPB Lock Bit Program command
This command is used to set the NVPB lock bit to ‘0’ thus locking the NVPBs, and
preventing them from being modified.
Read NVPB Lock Bit Status command
This command is used to read the status of the NVPB lock bit.
Password protection mode command set
The device accepts the commands belonging to the Password protection mode commands
set if and only if the Password protection mode lock bit (DQ2) has been set to '0', (see
section
commands are ignored.
Enter Password Protection Command Set command
Three bus write cycles are required to issue the Enter Password Protection Command Set
command. Once the command has been issued, only the commands related to the
password protection mode and the Exit Protection Command Set can be issued to the
device. Any other command is ignored.
Password Program command
The Password Program command is used to program the 64-bit password used in the
password protection mode.
To program the 64-bit password, the complete command sequence must be entered eight
times at eight consecutive addresses selected by A1-A0 plus DQ15A-1 in 8-bit mode, or
four times at four consecutive addresses selected by A1-A0 in 16-bit mode. The Password
Program command is a special kind of Program command and must be used according to
all the Program command timings. The result from this command can be verified by
checking the status register.
The password can be checked by issuing a Password Read command.
Once password program operation has completed, an Exit Protection Command Set
command must be issued to return the device to read mode. The password protection mode
can then be selected.
By default, all password bits are set to ‘1’.
Password Read command
The Password Read command is used to verify the password used in password protection
mode.
Section 5.4.3: Password protection mode lock bit
Section 5.2.2: Non-volatile protection bit lock
(DQ2)) otherwise the password
bit.
47/97