SAF1761BE/V1,557 NXP Semiconductors, SAF1761BE/V1,557 Datasheet - Page 61

no-image

SAF1761BE/V1,557

Manufacturer Part Number
SAF1761BE/V1,557
Description
Manufacturer
NXP Semiconductors
Datasheet

Specifications of SAF1761BE/V1,557

Lead Free Status / Rohs Status
Compliant

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
SAF1761BE/V1,557
Manufacturer:
NXP Semiconductors
Quantity:
10 000
NXP Semiconductors
Table 64.
SAF1761_1
Product data sheet
Bit
DW7
63 to 32
DW6
31 to 0
DW5
63 to 32
DW4
31 to 6
5
4 to 0
DW3
63
62
61
60
59
58
57
High-speed bulk IN and OUT: bit description
Symbol
reserved
reserved
reserved
reserved
J
NextPTDPointer
[4:0]
A
H
B
X
reserved
P
DT
Access
-
-
-
-
SW — writes -
SW — writes -
SW — sets
HW — resets
HW — writes -
HW — writes -
HW — writes -
SW — writes -
-
SW — writes
HW —
updates
HW —
updates
SW — writes
Value
-
-
-
0
-
-
-
-
Rev. 01 — 18 November 2009
Description
-
-
-
not applicable for asynchronous TD
Jump:
0 — To increment the PTD pointer.
1 — To enable the next PTD branching.
Next PTD Counter: Next PTD branching assigned by the PTD
pointer.
Active: Write the same value as that in V.
Halt: This bit corresponds to the Halt bit of the Status field of TD.
Babble: This bit corresponds to the Babble Detected bit in the
Status field of iTD, siTD or TD.
1 — When babbling is detected, A and V are set to 0.
Error: This bit corresponds to the Transaction Error bit in the
Status field of iTD, siTD or TD (Exec_Trans, the signal name is
xacterr).
0 — No PID error.
1 — If there are PID errors, this bit is set active. The A and V bits
are also set to inactive. This transaction is retried three times.
0 — Before scheduling.
-
Ping: For high-speed transactions, this bit corresponds to the Ping
state bit in the Status field of a TD.
0 — Ping is not set.
1 — Ping is set.
For the first time, software sets the Ping bit to 0. For the successive
asynchronous TD, software sets the bit in asynchronous TD based
on the state of the bit for the previous asynchronous TD of the
same transfer, that is:
Data Toggle: This bit is filled by software to start a PTD. If
NrBytesToTransfer[14:0] is not complete, software needs to read
this value and then write back the same value to continue.
The current asynchronous TD is completed with the Ping bit
set.
The next asynchronous TD will have its Ping bit set by the
software.
Hi-Speed USB OTG controller
SAF1761
© NXP B.V. 2009. All rights reserved.
61 of 166