PSB3186FV14NT Infineon Technologies, PSB3186FV14NT Datasheet - Page 52

no-image

PSB3186FV14NT

Manufacturer Part Number
PSB3186FV14NT
Description
Manufacturer
Infineon Technologies
Datasheet

Specifications of PSB3186FV14NT

Number Of Line Interfaces
1
Control Interface
HDLC
Lead Free Status / Rohs Status
Not Compliant
3.3.10
The ISAC-SX TE provides test and diagnostic functions for the S/T interface:
Note: For more details please refer to the application note “Test Function of new S-
– The internal local loop (internal Loop A) is activated by a C/I command ARL.
– The external local loop (external Loop A) is activated in the same way as the internal
– In remote line loop (RLP) received data is looped back to the S/T interface. The D-
Figure 27
Data Sheet
The transmit data of the transmitter is looped back internally to the receiver. The data
of the IOM-2 input B- and D-channels are looped back to the output B- and D-
channels.
The S/T interface level detector is enabled, i.e. if a level is detected this will be
reported by the Resynchronization Indication (RSY) but the loop function is not
affected.
Depending on the DIS_TX bit in the TR_CONF2 register the internal local loop can be
transparent or non transparent to the S/T line.
local loop described above. Additionally the EXLP bit in the TR_CONF0 register has
to be programmed and the loop has to be closed externally as described in
The S/T interface level detector is disabled.
This allows complete system diagnostics.
channel information received from the line card is transparently forwarded to the
output
IOM-2 D-channel. The output B-channel information on IOM-2 is fixed to ‘FF’
this test loop is active. The remote loop is programmable in TR_CONF2.RLP.
Transceiver family”
Test Functions
SCOUT-S(X)